Extra-fine particles improve lung delivery of inhaled steroids in infants: a study in an upper airway model.

نویسندگان

  • Hettie M Janssens
  • Johan C De Jongste
  • Wim C J Hop
  • Harm A W M Tiddens
چکیده

BACKGROUND The particles of a new hydrofluoroalkane-134a (HFA)-beclomethasone dipropionate (BDP) metered-dose inhaler (Qvar; 3M Pharmaceuticals; St. Paul, MN) are considerably smaller than those of chlorofluorocarbon (CFC)-BDP. This may improve lung deposition in infants who inhale nasally and have irregular breathing patterns and small airways. AIM To compare the dose delivered to the lungs of HFA-BDP and CFC-BDP at different breathing patterns using an upper airway model of an infant. METHODS An anatomically correct upper airway model of a 9-month-old child with an open nasal airway was connected to an impactor and breathing simulator. HFA-BDP, 100 microg, and CFC-BDP, 100 micro g, were delivered to the model through a detergent-coated, small-volume spacer. The total dose leaving the model (lung dose), its particle size distribution, and median mass aerodynamic diameter (MMAD) were assessed during simulated tidal breathing with tidal volumes (VTs) of 50 mL, 100 mL, and 200 mL, and 30 breaths/min. Dose was expressed as percentage of nominal dose. RESULTS Lung doses for HFA-BDP were 25.4%, 26.5%, and 30.7% compared with 6.8%, 4.8%, and 2.1% for CFC-BDP at VTs of 50 mL, 100 mL, and 200 mL, respectively. The dose of particles < 2.1 microm to the lung for HFA-BDP was 23 to 28% compared with 0.6 to 0.8% for CFC-BDP. The lung dose of CFC-BDP mainly consisted of particles between 2.1 microm and 4.7 microm. MMAD for HFA-BDP was 1.2 microm, and 2.6 to 3.3 microm for CFC-BDP depending on VT. The lung dose for CFC-BDP decreased significantly with increasing VT. HFA-BDP lung dose did not alter significantly with VT. CONCLUSIONS In this infant model study, the use of HFA-BDP with a high dose of particles < 2.1 microm improves the dose delivered to the lungs substantially. Furthermore, the large proportion of extra-fine particles in HFA-BDP results in lung doses less dependent on breathing pattern compared with CFC-BDP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro Particles Transport and Deposition in Realistic Geometry of Human Upper Airways

Realistic geometry of human upper airways from mouth to the end of trachea was reconstructed by implementing the CT-Scan images of a male subject.   A computational model for analyzing the airflow in the airways was developed and several simulations were performed.  To capture the anisotropy of the inhaled airflow in the upper airways, the Reynolds stress transport model of turbulence was used ...

متن کامل

Aerosol therapy: assume nothing and require data.

In this issue of RESPIRATORY CARE, Mitchell et al1 report a study in which they used a model of mechanical ventilation to examine differences in drug delivery between the hydrofluoroalkane (HFA) and chlorofluorocarbon (CFC) metered-dose inhaler (MDI) formulations of beclomethasone dipropionate (BDP). They discovered that the total emitted mass of drug at the end of the endotracheal tube (ETT) w...

متن کامل

Evaluation of the Droplet Collapsibility in Inhalation Drug Delivery through a 3D Computational Study

Background: Several multiphase flow analyses have been developed to predict the fate of particles used in inhalation drug delivery; however, the collapse of droplets during their passage through respiratory tract has not been investigated. Objective: To assess the probability of droplet collapse in the upper respiratory tract.Methods: A 3D model of mouth-to-second generation airway after the tr...

متن کامل

Inhaled Aerosol Distribution in Human Airways: A Scintigraphy-Guided Study in a 3D Printed Model.

BACKGROUND While it is generally accepted that inertial impaction will lead to particle loss as aerosol is being carried into the pulmonary airways, most predictive aerosol deposition models adopt the hypothesis that the inhaled particles that remain airborne will distribute according to the gas flow distribution between airways downstream. METHODS Using a 3D printed cast of human airways, we...

متن کامل

A randomised controlled trial of small particle inhaled steroids in refractory eosinophilic asthma (SPIRA)

BACKGROUND Some patients with refractory asthma have evidence of uncontrolled eosinophilic inflammation in the distal airways. While traditional formulations of inhaled steroids settle predominantly in the large airways, newer formulations with an extra-fine particle size have a more peripheral pattern of deposition. Specifically treating distal airway inflammation may improve asthma control. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 123 6  شماره 

صفحات  -

تاریخ انتشار 2003