Identification of aerobic Gram-positive bacilli by use of Vitek MS.

نویسندگان

  • Maria Navas
  • David H Pincus
  • Kathy Wilkey
  • Linda Sercia
  • Margaret LaSalvia
  • Deborah Wilson
  • Gary W Procop
  • Sandra S Richter
چکیده

The accuracy of Vitek MS mass spectrometric identifications was assessed for 206 clinically significant isolates of aerobic Gram-positive bacilli representing 20 genera and 38 species. The Vitek MS identifications were correct for 85% of the isolates (56.3% to the species level, 28.6% limited to the genus level), with misidentifications occurring for 7.3% of the isolates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.

BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in ...

متن کامل

Multicenter evaluation of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of Gram-positive aerobic bacteria.

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 sy...

متن کامل

Use of MALDI-TOF mass spectrometry after liquid enrichment (BD Bactec™) for rapid diagnosis of bone and joint infections.

Advantages of MALDI-TOF MS (MS) were evaluated for diagnosis of bone and joint infections after enrichment of synovial fluid (SF) or crushed osteoarticular samples (CSs). MS was performed after enrichment of SF or crushed osteoarticular samples CS (n = 108) in both aerobic and anaerobic vials. Extraction was performed on 113 vials (SF: n = 47; CS: n = 66), using the Sepsityper® kit prior identi...

متن کامل

Performance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.

We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS cor...

متن کامل

Direct Identification and Antimicrobial Susceptibility Testing of Bacteria From Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry and the Vitek 2 System

BACKGROUND We evaluated the reliability and accuracy of the combined use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) bacterial identification and Vitek 2 antimicrobial susceptibility testing (AST) for bacteria from positive blood culture bottles. METHODS Direct identification and AST were performed in parallel to the standard methods in monom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2014