CMOS Readout System for a Double-sided Germanium Strip Detector

نویسندگان

  • R. A. Kroeger
  • W. N. Johnson
  • J. D. Kurfess
چکیده

A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discriminator, and peak detection circuitry. All circuits are designed to operate at low power. Circuits have been duplicated in both NMOS and PMOS to provide both polarities of signals. We have constructed an 8×8 channel system to test these prototype chips. Power consumption for the preamplifier through peak-detector circuit is 4 mW/channel. The test system has a conversion gain of ~35 mV/fC, system noise (equivalent noise charge) of ENC<220 e rms (0 pF), and a dynamic range of >100:1 in both NMOS and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly segmented thin microstrip detector with data-driven fast readout

In September 2008 the Slim5 [1] collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology, providing digital sparsified readout. The other...

متن کامل

Double-sided Silicon Detectors using N-side Pad Readout for the CMS Silicon Inner Tracker

Double-sided silicon detector prototypes produced for the CMS inner tracker are described which divide the n-side into pads rather than strips. The signal routing to the readout electronics is made on a separate flexible z-print which is glued on the detector and then wire-bonded to the pads.

متن کامل

A Preamplifier-Shaper-Stretcher Integrated Circuit System for Use with Germanium Strip Detectors

A 16-channel Integrated Circuit readout electronics chip is being developed for use with a germanium strip detector. Such a system will provide superior energy resolution with 2dimensional imaging in a single instrument that can be used for X-ray imaging and nuclear line gamma-ray spectroscopy. As part of the total ASIC development, prototype ICs of a typical channel have been designed, fabrica...

متن کامل

Charge Sensitive Preampli er and Pulse Shaper using CMOS process for Germanium Spectroscopy

We have developed a low noise, low power charge sensitive ampli er and pulse shaping circuit. Our application is for a double-sided germanium strip detector, nominally providing 50 independent spectroscopy channels. An array of these detectors would provide signi cant improvements in imaging, spectroscopy, and sensitivity for space-based gamma-ray astronomy. The key features of these electronic...

متن کامل

Readout System for PANDA Silicon Strip Prototyp Studies

The PANDA Experiment at FAIR will include a MicroVertex-Detector (MVD) for tracking and vertexing. The MVD will be composed of silicon pixel detectors and double-sided silicon strip detectors. The strip part will contain approximately 200,000 channels that need to be read out with highly integrated front-ends. A specific feature of the PANDA detector is the data acquisition concept [1]. Contrar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997