Changes in atrioventricular conduction and predictors of pacemaker need after percutaneous implantation of the CoreValve®. Aortic valve prosthesis.
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVES Although changes in atrioventricular conduction frequently occur after percutaneous implantation of an aortic valve prosthesis, little is known about the mechanisms involved or how these changes progress. We investigated ECG abnormalities and predictors of pacemaker need after percutaneous implantation of the CoreValve® aortic valve prosthesis. METHODS Between April 2008 and October 2009, 65 patients with symptomatic severe aortic stenosis received a CoreValve® prosthesis. Clinical and ECG parameters were recorded and predictors of pacemaker need due to advanced atrioventricular block were investigated. The analysis excluded three patients because they had pacemakers and a fourth who died during the procedure. RESULTS The patients' mean age was 79 ± 7.8 years and their logistic EuroSCORE was 20 ± 14%. Implantation was successful in 98.4%. After implantation, 47.5% had left bundle branch block and 21 patients (34.4%) required a permanent pacemaker. The need for a pacemaker was associated with a greater depth of prosthesis implantation in the left ventricular outflow tract (LVOT): 13 ± 2.5 mm vs. 8.8 ± 2.8 mm (P< .001). Moreover, depth was the only predictor: odds ratio 1.9, 95% confidence interval 1.19-3.05 (P< .007). A cutpoint of 11.1 mm for the prosthesis depth in the LVOT had a sensitivity of 81% and a specificity of 84.6% for predicting the need for a pacemaker. CONCLUSIONS After CoreValve® aortic valve prosthesis implantation, a high percentage of patients needed a permanent pacemaker for advanced atrioventricular block. The only independent predictor was the depth of the prosthesis in the LVOT, which could serve as an early indicator of pacemaker need.
منابع مشابه
Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.
INTRODUCTION AND OBJECTIVES Conduction disturbances often occur after CoreValve transcatheter aortic valve implantation. The aim was to analyze which cardiac conduction changes occur in patients with aortic stenosis treated with this type of prosthesis. METHODS A total of 181 patients with severe aortic stenosis treated with this prosthesis and studied by electrocardiography between April 200...
متن کاملDepth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.
BACKGROUND Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. METHODS AND RESULTS We aimed to evaluate the implantatio...
متن کاملCause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study.
Transcatheter aortic valve implantation is being established as an alternative treatment for some patients with symptomatic severe aortic stenosis who are not considered suitable for surgical aortic valve replacement because of prohibitive surgical risk.1–3 One of the potential complications is complete atrioventricular block requiring definitive pacemaker implantation. This complication occurs...
متن کاملIncidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis.
BACKGROUND Previous reports have suggested the occurrence of cardiac conduction disorders and permanent pacemaker (PPM) requirement after transcatheter aortic valve implantation (TAVI). Based on a single-center experience, we aim to assess the incidence of postprocedural conduction disorders, need for PPM, and its determinants after TAVI with a self-expanding bioprosthesis. METHODS From Augus...
متن کاملIncreased Pacemaker Implantation Rate After New-Generation Balloon-Expandable SAPIEN 3 Valve: Who Was to Blame, the Valve or the Doctor?
SEE PAGE 805 T he occurrence of conduction disturbances and the need for permanent pacemaker implantation remain a significant issue associated with transcatheter aortic valve replacement (TAVR) (1). Indeed, the contiguity of the conduction system to the aortic annulus (landing zone of transcatheter valve prostheses) makes this procedure likely to develop this complication (2). To date, several...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 63 12 شماره
صفحات -
تاریخ انتشار 2010