Ultrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast
نویسندگان
چکیده
INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/T1) image contrast. They have been explored for lesion characterization in the liver and, more recently, in the breast [1]. However, b-SSFP sequences are very sensitive to B0 inhomogeneities, manifesting as banding artifacts and posing major challenges to robust fat suppression in the breast and at high field strengths. We investigated a new 3D technique that combines balanced steady-state free precession imaging with a two-point Dixon fat-water reconstruction algorithm [2] for robust fat-separated volumetric imaging of the breast with near isotropic spatial resolution in short scan times.
منابع مشابه
Breast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE
INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...
متن کاملCoronary artery imaging at 3T using a novel ECG gated SSFP-Dixon sequence and a motion insensitive view ordering scheme
Purpose: MR Coronary Artery Imaging (CAI) remains challenging due to the need for high spatial resolution as well as due to constraints imposed by physiological motion and the stringent requirements for fat and muscle suppression to visualize the arterial signal with good contrast. 3D ECG gated balanced steady state free precession (SSFP) imaging has shown great promise due to its high SNR, exc...
متن کاملFull-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T.
Passband balanced-steady-state free precession (b-SSFP) fMRI is a recently developed method that utilizes the passband (flat portion) of the b-SSFP off-resonance response to measure MR signal changes elicited by changes in tissue oxygenation following increases in neuronal activity. Rapid refocusing and short readout durations of b-SSFP, combined with the relatively large flat portion of the b-...
متن کاملImproved Fat Suppression With High Resolution Balanced Steady State Imaging in the Breast
(a) because of the variable level of fat suppression. Both 3DPR-SSFP with WC-SSFP (b) and IDEAL 3DPR-SSFP (c) provide a more consistent level of fat suppression allowing for better delineation of fine fibroglandular structure. IDEAL 3DPR-SSFP (c) also resolves fat-water swap due to B0 inhomogeneity in superior region of the breast. Red arrows: Note tiny gap in fibroglandular tissue in WC SSFP (...
متن کاملHigh Resolution Cartilage and Whole Organ Knee Joint Assessment: 3D Radial Fat-Suppressed Alternating TR SSFP
INTRODUCTION Effective cartilage imaging and whole organ joint assessment requires both high isotropic resolution and fat suppression or separation. SSFP lends itself to this task as it rapidly creates high signal-to-noise ratio (SNR) and T2-like contrast with bright fluid signal. However, SSFP also produces bright fat signal which may interfere with visualization of the critical cartilage/bone...
متن کامل