Clinical experience with Ex-press Mini Glaucoma Shunt implantation.

نویسندگان

  • Morena Gavrić
  • Nikica Gabrić
  • Jurica Jagić
  • Ana Cović
چکیده

In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 patients with POAG (60%) and 14 patients with PEXG-pseudoexfoliation glaucoma (40%). The follow-up period was 8.62 + 7.48 months (range 2-22 months). Main outcome measures included postoperative IOP control, postoperative medications and early postoperative complications. The IOP was measured in the following postoperative time-points of 1 day, 1 week, 1, 3, 6, 9 and 12 months. The mean IOP values 1 year postoperatively were reduced for 52.8% compared to preoperative values and the use of medications were reduced for 77%. We had complications like postoperative hypotony (3.5%), choroidal ablation (7%), intraocular hemorrhage (3.5%) and postoperative shunt closure (3.5%). The Ex PRESS Mini Glaucoma Shunt implanted under a superficial scleral flap is relatively safe and effective surgical procedure and provides satisfactory IOP control and medication reduction. However, device related complications remain still a problem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma.

PURPOSE To evaluate the intraocular pressure (IOP) control and graft survival after Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma. METHODS The study included postpenetrating keratoplasty glaucoma cases unresponsive to medical antiglaucomatous therapy in whom 15 Ex-PRESS mini glaucoma shunt implantation was carried out. All glaucoma shunt implant...

متن کامل

Combined procedure of phacoemulsification and implantation of Ex-PRESS miniature glaucoma shunt.

Glaucoma patients not responding to maximum medical therapy with coexistent cataract are candidates for combined cataract and glaucoma therapy. There are different therapy models. The choice of therapy depends on numerous patient and surgeon related factors. Ex-PRESS mini glaucoma shunt is a modified trabeculectomy and can be combined with cataract surgery when indicated. In this paper we prese...

متن کامل

A comparison of the Ex-PRESS™ mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma.

BACKGROUND AND OBJECTIVE To compare the success and complication rates of patients with glaucoma who had an Ex-PRESS mini glaucoma shunt device implantation (Optonol, Ltd., Neve Ilan, Israel) to those who had conventional trabeculectomy. PATIENTS AND METHODS The records of 76 eyes of 69 consecutive subjects who had Ex-PRESS implants and 77 eyes of 65 consecutive controls who had trabeculectom...

متن کامل

Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review

PURPOSE The aim of this study was to compare the efficacy and safety between standard trabeculectomy and the Ex-PRESS shunt implantation. METHODS A retrospective review of the records of 100 eyes of 100 patients who underwent trabeculectomy or Ex-PRESS shunt implantation between July 2010 and June 2012 was conducted. Of these, 61 (61%) eyes underwent trabeculectomy and 39 (39%) eyes underwent...

متن کامل

Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

PURPOSE To report a case of corneal decompensation due to the Ex-PRESS(®) mini glaucoma shunt device (Ex-PRESS). PATIENT AND METHODS A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months. RESULTS We observed partial decompensation of the corneal endothelium adjacent to the filterin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 35 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2011