Structural analysis of a bileaflet mechanical heart valve prosthesis with curved leaflet

نویسنده

  • Young Joo Kwon
چکیده

Structural analysis, especially the thickness effect on the structural strength, of a bileaflet mechanical heart valve prosthesis with curved leaflets is presented in this paper. Taking the wide variations of the blood flow pressure on the leaflet surface, the structural stresses inside the leaflet and deflections of the leaflet are investigated by adopting both linear and nonlinear structural analysis techniques for more accurate results comparison. The thickness of the curved leaflet also varies considerably from 0.50 mm to 0.75 mm by 0.05 mm. These are very useful for the design of the mechanical heart valve (MHV) prosthesis. Linear and nonlinear structural mechanic analyses for the leaflet of the MHV prosthesis are conducted to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that the structural strength of the leaflet decreases as the leaflet thickness becomes thinner and thinner, and the nonlinear structural behaviors of thin leaflets are very conspicuous for large applied blood pressures. Hence, these thin leaflets are not desirable for the in vivo use of the MHV prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leaflet Escape in a New Bileaflet Mechanical Valve

Background—Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. Methods and Results—At the University of Padua, between November 2000 and ...

متن کامل

Leaflet escape in a new bileaflet mechanical valve: TRI technologies.

BACKGROUND Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. METHODS AND RESULTS At the University of Padua, between November 2000 an...

متن کامل

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwen...

متن کامل

Direct imaging of bileaflet mechanical valve behavior in the tricuspid position.

OBJECTIVE The optimal orientation of a bileaflet mechanical valve for tricuspid valve replacement (TVR) has not yet been determined. The aim of this study was to use fiberoptic cardioscopy to evaluate the effect of orientation of a mechanical valve implanted in the tricuspid position on bileaflet mechanical valve behavior. METHODS Twelve pigs (50-59 kg) underwent TVR with a St. Jude Mechanica...

متن کامل

Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve

BACKGROUND Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008