Spontaneous Rotation of a Toric Implantable Collamer Lens
نویسندگان
چکیده
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 -4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months' follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.
منابع مشابه
JOURNAL OF MEDICAL CASE REPORTS Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...
متن کاملPosterior Chamber Toric Implantable Collamer Lenses – Literature Review
Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...
متن کاملSuccessful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
INTRODUCTION We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. CASE PRESENTATION A 53-year-old woman had undergone toric implan...
متن کاملToric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes
PURPOSE The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. METHODS Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was -4. 98 ± 3.49 ...
متن کاملLens vacuoles during phakic intraocular lens implantation
Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...
متن کامل