Paraprotein interference in an assay of conjugated bilirubin.

نویسندگان

  • Andrea Nauti
  • Alessandra Barassi
  • Giampaolo Merlini
  • Gian Vico Melzi d'Eril
چکیده

References 1. Lo YMD, Hjelm NM, Fidler C, Sargent IL, Murphy MF, Chamberlain PF, et al. Prenatal diagnosis of fetal RhD status by molecular analysis of maternal plasma. N Engl J Med 1998;339:1734–8. 2. Chiu RWK, Lau TK, Leung TN, Chow KCK, Chui DHK, Lo YMD. Prenatal exclusion of thalassaemia major by examination of maternal plasma. Lancet 2002;360:998–1000. 3. Zhong XY, Laivuori H, Livingston JC, Ylikorkala O, Sibai BM, Holzgreve W, et al. Elevation of both maternal and fetal extracellular circulating deoxyribonucleic acid concentrations in the plasma of pregnant women with preeclampsia. Am J Obstet Gynecol 2001;184:414–9. 4. Ng EKO, Leung TN, Tsui NBY, Lau TK, Panesar NS, Chiu RWK, et al. The concentration of circulating corticotropin-releasing hormone mRNA in maternal plasma is increased in preeclampsia. Clin Chem 2003;49:727–31. 5. Lo YMD, Tein MS, Lau TK, Haines CJ, Leung TN, Poon PM, et al. Quantitative analysis of fetal DNA in maternal plasma and serum: implications for noninvasive prenatal diagnosis. Am J Hum Genet 1998;62:768–75. 6. Dhallan R, Au WC, Mattagajasingh S, Emche S, Bayliss P, Damewood M, et al. Methods to increase the percentage of free fetal DNA recovered from the maternal circulation. JAMA 2004;291:1114–9. 7. Chung GTY, Chiu RWK, Chan KCA, Lau TK, Leung TN, Lo YMD. Lack of dramatic enrichment of fetal DNA in maternal plasma by formaldehyde treatment. Clin Chem 2005;51:655–8. 8. Lo YMD, Chiu RWK, Chan KCA, Chung GTY. Free fetal DNA in maternal circulation. JAMA 2004;292:2835. 9. Tsui NBY, Ng EKO, Lo YMD. Stability of endogenous and added RNA in blood specimens, serum, and plasma. Clin Chem 2002;48:1647–53. 10. Ng EKO, Tsui NBY, Lau TK, Leung TN, Chiu RWK, Panesar NS, et al. mRNA of placental origin is readily detectable in maternal plasma. Proc Natl Acad Sci U S A 2003;100:4748–53. 11. Ding J, Ichikawa Y, Ishikawa T, Shimada H. Effect of formalin on extraction of mRNA from a formalin-fixed sample: a basic investigation. Scand J Clin Lab Invest 2004;64:229–35.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference in laboratory tests

Interference in clinical laboratory testing can create discrepancies in test results which can lead to patient harm.  In clinical chemistry, interference is defined as a cause of medically significant difference in the measurand test result due to another component or property of the sample. Interference by endogenous and exogenous substances with assays for clinical analytes is a common prob...

متن کامل

Characterization of sulfasalazine's interference in the measurement of conjugated bilirubin by the Ektachem slide method.

We describe the cases of four patients who were taking sulfasalazine for inflammatory bowel disease, whose conjugated bilirubin concentrations in serum exceeded their corresponding total bilirubin concentrations as measured with a multilayer film analyzer, the Ektachem 400. Sulfasalazine added to pooled human serum at therapeutic concentrations increased the apparent conjugated bilirubin, as me...

متن کامل

Sensitive high-pressure liquid chromatographic assay for amphotericin B which incorporates an internal standard.

We developed a rapid, sensitive, high-pressure liquid chromatographic (HPLC) procedure which incorporates a commercially available internal standard, 1-amino-4-nitronaphthalene, to measure amphotericin B in serum. Recovery was quantitative (greater than or equal to 90%), and the standard curve was linear from 0.04 to at least 10.0 micrograms/ml. The reproducibility of the assay was good, with i...

متن کامل

A simple, solid-phase iodine-125 radioimmunoassay for theophylline.

The activity of y-glutamyltransferase (EC 2.3.2.2) is measured on the DuPont aca by an adaptation of the Szasz procedure ;-y-glutamyl-p-nitroanilide is transferred to glycylglycine, thereby releasing p-nitroaniline, which is measured at 405 nm. I have noticed low glutamyltransfer-ase activity in patients with cholestasis wherealkaline phosphate (EC 3.1.3.1) is increased, total bilirubin> 100 mg...

متن کامل

immunofixation on Thin-Layer Agarose

Na2CO3. After 1 mm, 1.0mL of alkaline picrate reagent (500 mL saturated picric acid, 100 mL of 1 mol/L NaOH, and 1 mL of Triton X-100 per liter) is added. The absorbance change at 505 nm and 37 #{176}C is measured between 48 s and 7 mm after adding the picrate reagent. Under these conditions, samples of pooled sera from jaundiced patients showed negative interference, 35 mg of total bilirubin p...

متن کامل

Determination of conjugated and total bilirubin in serum of neonates, with use of bilirubin oxidase.

A new, simple, and rapid assay for conjugated bilirubin that does not require serum-matrix standards was developed by using the enzyme bilirubin oxidase (EC 1.3.3.5). This procedure can also be modified to measure total bilirubin. Measurements from these assays were compared with results obtained with the Sigma 605 (Jendrassik-Gróf method), Sigma 550/551 (Walters-Gerarde method), and Kodak Ekta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 2005