چکیده

Hybrid imaging devices combining Positron-Emission-Tomography (PET) with Magnetic-Resonance-Imaging (MRI) have been shown to possess a great potential for small animal studies. Recently PET/MR systems have also been built for human applications. Here we present an evaluation of the first hybrid PET/MR device, which has the capabilities to perform simultaneous PET/MR acquisitions of the human brain. The influence of the PET insert on the MR imaging performance was evaluated. Furthermore fundamental PET parameters were accessed with and without MR sequences running. In vivo PET/MR studies of patients have been performed, where the attenuation correction for the PET was based on MR data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary evaluation of image quality in a new clinical ToF-PET/MR scanner.

GE Healthcare, Waukesha, USA A new ToF-PET/MR scanner has recently been deployed at the University Hospital of Zurich for clinical evaluation purposes. The goal of the present work was to compare the image quality obtained on this system with that of equivalent state-of-the-art standalone scanners. The GE Signa PET/MR is a whole-body scanner combining a 3T wide-bore MR system with a 25 cm PET d...

متن کامل

Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

PURPOSE To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. MATERIALS AND METHODS A total of 75 consecutive patients were evaluated in t...

متن کامل

Initial experience in hybrid PET-MRI for evaluation of refractory focal onset epilepsy

PURPOSE We aim to evaluate the utility/improved accuracy of hybrid PET/MR compared to current practice separate 3T MRI and PET-CT imaging for localization of seizure foci. METHOD In a pilot study, twenty-nine patients undergoing epilepsy surgery evaluation were imaged using PET/MR. This subject group had 29 previous clinical 3T MRI as well as 12 PET-CT studies. Prior clinical PET and MR image...

متن کامل

Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

OBJECTIVE The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. METHODS According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General El...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...