Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial.
نویسندگان
چکیده
OBJECTIVE To assess the accuracy of general practitioners, practice nurses, and interpretative software in the use of different types of electrocardiogram to diagnose atrial fibrillation. DESIGN Prospective comparison with reference standard of assessment of electrocardiograms by two independent specialists. SETTING 49 general practices in central England. PARTICIPANTS 2595 patients aged 65 or over screened for atrial fibrillation as part of the screening for atrial fibrillation in the elderly (SAFE) study; 49 general practitioners and 49 practice nurses. INTERVENTIONS All electrocardiograms were read with the Biolog interpretative software, and a random sample of 12 lead, limb lead, and single lead thoracic placement electrocardiograms were assessed by general practitioners and practice nurses independently of each other and of the Biolog assessment. MAIN OUTCOME MEASURES Sensitivity, specificity, and positive and negative predictive values. RESULTS General practitioners detected 79 out of 99 cases of atrial fibrillation on a 12 lead electrocardiogram (sensitivity 80%, 95% confidence interval 71% to 87%) and misinterpreted 114 out of 1355 cases of sinus rhythm as atrial fibrillation (specificity 92%, 90% to 93%). Practice nurses detected a similar proportion of cases of atrial fibrillation (sensitivity 77%, 67% to 85%), but had a lower specificity (85%, 83% to 87%). The interpretative software was significantly more accurate, with a specificity of 99%, but missed 36 of 215 cases of atrial fibrillation (sensitivity 83%). Combining general practitioners' interpretation with the interpretative software led to a sensitivity of 92% and a specificity of 91%. Use of limb lead or single lead thoracic placement electrocardiograms resulted in some loss of specificity. CONCLUSIONS Many primary care professionals cannot accurately detect atrial fibrillation on an electrocardiogram, and interpretative software is not sufficiently accurate to circumvent this problem, even when combined with interpretation by a general practitioner. Diagnosis of atrial fibrillation in the community needs to factor in the reading of electrocardiograms by appropriately trained people.
منابع مشابه
Accuracy of ECG interpretation in primary care was limited for detecting atrial fibrillation.
ED FROM Mant J, Fitzmaurice DA, Hobbs FDR, et al. Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial. BMJ 2007;335:380. Correspondence to: Dr D A Fitzmaurice, University of Birmingham, Birmingham, UK; [email protected] So...
متن کاملIncidence of Atrial Fibrillation after Coronary Artery Bypass Graft Surgery and Its Risk Factors in Shiraz, Iran during 2017-18
Background and Objectives: Atrial fibrillation is one of the most common disorientations after coronary artery bypass graft surgery and can affect the chance of survival in the first year after surgery. The present study aimed to determine the incidence of atrial fibrillation after coronary artery bypass graft surgery and its risk factors. Methods: This cross-sectional study was performed on...
متن کاملDetecting and Diagnosing Atrial Fibrillation (D2AF): study protocol for a cluster randomised controlled trial.
BACKGROUND Atrial fibrillation is a common cause of stroke and other morbidity. Adequate treatment with anticoagulants reduces the risk of stroke by 60 %. Early detection and treatment of atrial fibrillation could prevent strokes. Atrial fibrillation is often asymptomatic and/or paroxysmal. Case-finding with pulse palpation is an effective screening method, but new methods for detecting atrial ...
متن کاملسنجش استعداد ابتلا به فیبریلاسیون دهلیزی با استفاده از تحلیلهای غیر خطی سیگنال الکتروکاردیوگرام
Atrial Fibrillation is a supra ventricular tachyarrhythmia, which is characterized by the deterioration of atrial mechanical function and aberrant. It has become a social and economic problem because a large percentage of the world population suffering from this disease. The early diagnosis of this fatal cardiac Arrhythmia can be prevented and managed it. In this study, we used non-invasive met...
متن کاملThe effects of Vitamin C on Inflammatory Markers and Atrial Fibrillation in Patients Undergoing Coronary Artery Bypass Surgery in Bushehr Heart Center: A Randomized Controlled Clinical Trial
Background: Coronary artery bypass graft surgery (CABG) with cardiopulmonary bypass pump may cause systemic inflammatory reactions by releasing cytokines which leads to multiple organ failure. Vitamin C has anti-inflammatory and antioxidant properties. The study aimed to determine the effect of vitamin C on inflammatory markers and atrial fibrillation in patients undergoing CABG. Materials and ...