Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

نویسندگان

  • C E Traverso
  • F De Feo
  • A Messas-Kaplan
  • P Denis
  • S Levartovsky
  • E Sellem
  • F Badalà
  • Z Zagorski
  • A Bron
  • S Gandolfi
  • M Belkin
چکیده

AIM To evaluate the efficacy and safety of a stainless steel miniature glaucoma drainage device (Ex-PRESS R50) for the surgical treatment of primary open angle glaucoma (POAG) and cataract when combined with phacoemulsification. METHODS Clinical, prospective, multicentre, single treatment arm, non-randomised, non-masked study. The Ex-PRESS device was implanted at the limbus under a conjunctival flap. Phacoemulsification cataract extraction and in the bag IOL implantation were performed through clear cornea temporally. PRIMARY OUTCOME IOP change; secondary outcomes: side effects and VA changes. RESULTS 26 eyes of 25 patients were implanted with the device. The mean (SD) follow up was 23.9 (10.4) months and the mean age was 75.1 (7.1) years. 17/26 eyes have more than 3 years of follow up. One case was discontinued because of device removal, one because of death, and three were lost to follow up. EFFICACY preoperative IOP was 21 (4) mm Hg; at 1, 2, and 3 years IOP was 15.3 (3.1) mm Hg (35% reduction), 16.6 (2.7) mm Hg (29% reduction), and 16 (2.6) mm Hg (22% reduction) respectively. Kaplan-Meyer determined overall success rate (IOP < or = 21 mm Hg at the last visit with or without medications) as 76.9%. The number of antiglaucoma medications was reduced by 95% at year 1. Only six patients (23%) were taking IOP lowering treatment at their last visit, five with one medication and one with two medications. Side effects: early postoperative complications were clinically mild and included six cases of hypotony (IOP <5 mm Hg), three cases of hyphaema (<2 mm) with no clinically significant further effects. Long term complications were two cases (7.7%) of device rotation (one treated by reposition) and three cases (11.5%) of conjunctival erosion at 2 and 3 years. CONCLUSIONS The Ex-PRESS implant, combined with phacoemulsification cataract extraction, is clinically safe and effective, maintaining in the long term a large reduction in IOP and in the number of antiglaucoma medications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.

AIM To evaluate the efficacy and safety of glaucoma drainage device Ex-PRESS(®) P-50 for combined cataract surgery and glaucoma. METHODS Patients having cataract and open angle glaucoma or patients with open advanced glaucoma which needed two or more antiglaucoma medications were included. Combined cataract surgery and glaucoma with Ex-PRESS(®) P-50 model placed under scleral flap was perform...

متن کامل

[Postoperative outcomes after combined glaucoma surgery. Comparison of ex-press miniature implant with standard trabeculectomy].

PURPOSE To evaluate postoperative outcomes and success after combined phacoemulsification and glaucoma surgery with Ex-PRESS miniature implant compared with combined surgery with standard trabeculectomy. METHODS In this prospective series of 40 consecutive eyes we compared 20 eyes in 17 patients treated with combined phacoemulsification and glaucoma filtering surgery with the Ex-PRESS miniatu...

متن کامل

Ocular hypertension after intravitreal triamcinolone with vitrectomy and phacoemulsification

OBJECTIVE To evaluate the effect of adjunctive intravitreal triamcinolone (IVTA) on intraocular pressure (IOP) in the setting of combined vitrectomy with phacoemulsification. DESIGN Retrospective case series. PARTICIPANTS One hundred thirty-one consecutive eyes undergoing nonemergent vitrectomy with phacoemulsification and IVTA were reviewed and included in the analysis. All 131 eyes receiv...

متن کامل

Evaluation of Ex-PRESS implantation combined with phacoemulsification in primary angle-closure glaucoma

To evaluate the safety and efficacy of Ex-PRESS (R50) implantation combined with phacoemulsification in primary angle-closure glaucoma (PACG) patients with cataract.Twenty-four eyes of 24 patients with unregulated PACG underwent combined cataract and glaucoma surgery. After phacoemulsification and intraocular lens implantation, the Ex-PRESS (R-50) was inserted into the anterior chamber under a ...

متن کامل

Combined phacoemulsification and Ahmed valve glaucoma drainage implant: a retrospective case series.

PURPOSE To report on the efficacy and safety of combined phacoemulsification and an Ahmed valve glaucoma drainage implant with respect to visual acuity improvement, intraocular pressure (IOP) control, and requirement for antiglaucoma medication. METHODS A retrospective chart review was conducted of 41 eyes (31 patients) with coexisting visually significant cataracts and uncontrolled glaucoma ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 89 4  شماره 

صفحات  -

تاریخ انتشار 2005