Suitability of various control sera for use in testing the accuracy of cholesterol determination with enzymic kits.
نویسندگان
چکیده
We used 20 different commercial enzymic kits to measure cholesterol in 19 commercial control sera and in a pooled specimen of human serum and compared the relative biases, with the Abell -Kendall procedure as reference. Our purpose was to select those sera in various enzymic kits showing behavior similar to that of human serum and which thus can be used to measure the accuracy of these kits. The overall mean relative biases obtained with each of the 20 kits for the pooled human serum on the one hand and for a given control serum on the other generally correlated significantly. On the basis of the correlation coefficients and regression equations, we could select the control sera best suited for measurement of accuracy. They were all human-serum based, with cholesterol concentrations greater than 5 mmol/L. Animal sera with above-normal lipid values produced by feeding special diets appeared to be less reliable control sera in this respect.
منابع مشابه
Applicability of various quality-control sera to assay of high-density lipoprotein cholesterol.
Effective internal quality control and external quality assessment of high-density lipoprotein cholesterol assay is made difficult by analyte instability, and the suitability of quality-control sera for this purpose has not been studied. We have therefore investigated the properties of 25 different control sera from 15 suppliers by estimating within-batch precision for the two precipitation pro...
متن کاملTesting the accuracy of total cholesterol assays in an external quality-control program. Effect of adding sucrose to lyophilized control sera compared with use of fresh or frozen sera.
We studied the suitability of various types of human serum preparations to test the accuracy of total cholesterol measurements in the External Quality Assessment scheme in The Netherlands, in which approximately 180 laboratories participate. Checked against the certified Abell/Kendall Reference Method, large reagent-dependent negative biases were observed with lyophilized serum that was insuffi...
متن کاملHigh-density-lipoprotein cholesterol in heparin-MnCl2 supernates determined with the Dow enzymic method after precipitation of Mn2+ with HCO3-.
Manganese interferes with enzymic cholesterol methods. In this study, we enzymically measured high-density-lipoprotein (HDL) cholesterol in heparin-Mn2+ supernates that had been treated with NaHCO3 (91 mmol/L) to precipitate Mn2+, and compared results with those by an automated Liebermann- Burchard method. For untreated supernates of 96 fresh plasma samples, the enzymic values were 10.4% higher...
متن کاملDetermination of Best Supervised Classification Algorithm for Land Use Maps using Satellite Images (Case Study: Baft, Kerman Province, Iran)
According to the fundamental goal of remote sensing technology, the image classification of desired sensors can be introduced as the most important part of satellite image interpretation. There exist various algorithms in relation to the supervised land use classification that the most pertinent one should be determined. Therefore, this study has been conducted to determine the best and most su...
متن کاملImproved preparation of cholesterol calibration and control sera.
We prepared several serum batches with various cholesterol concentrations, to be used as calibrators and controls in a proficiency testing program of an organization in The Netherlands that is in charge of the standardization of cholesterol determinations for epidemiological purposes. The sera were of human origin, to avoid abnormal matrix effects. To decrease the cholesterol content in some sa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 6 شماره
صفحات -
تاریخ انتشار 1984