Radiation Detectors in High Energy Physics*
نویسنده
چکیده
Spark chambers, scintillation and Cerenkov detectors are used extensively in high energy physics experiments. The potential usefulness of semiconductor detectors is being investigated. There is a need for detectors which will identify very high energy particles. The various types of spark chambers are briefly reviewed, including narrow gap, wide gap and filmless chambers. Applications of scintillation detectors are discussed, together with remarks on light pipes, localization of particles by time-of-flight, use of multiparameter pulse height analysis, hodoscopes and on-line computers. The use of Cerenkov counters is summarized. Several new types of detectors are considered which may be suitable for identification of particles of very high energy, hundreds of BeV, including transition radiation detectors and semiconductor devices.
منابع مشابه
Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملRadiation Damage in Silicon Detectors for High-Energy Physics Experiments
Radiation effects in silicon detectors are discussed in view of their application in future high-energy physics experiments. An overview is given of the major changes in the operational parameters due to radiation damage and their origin in the radiation-induced microscopic disorder in the silicon bulk. The principal radiation hardening technologies are described that have been adopted by the h...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملRadiation Effects on the On-line Monitoring System of a Hadrontherapy Center
Introduction Today, there is a growing interest in the use of hadrontherapy as an advanced radiotherapy technique. Hadrontherapy is considered a promising tool for cancer treatment, given its high radiobiological effectiveness and high accuracy of dose deposition due to the physical properties of hadrons. However, new radiation modalities of dose delivery and on-line beam monitoring play crucia...
متن کاملRadiation Hardness of Silicon Detectors - A Challenge from High Energy Physics
An overview of the radiation damage induced problems connected with the application of silicon particle detectors in future high energy physics experiments is given. Problems arising from the expected hadron fluences are summarized and the use of the nonionizing energy loss for normalization of bulk damage is explained. The present knowledge on the deterioration effects caused by irradiation is...
متن کامل