An automated integrated platform for rapid and sensitive multiplexed protein profiling using human saliva samples.

نویسندگان

  • Shuai Nie
  • W Hampton Henley
  • Scott E Miller
  • Huaibin Zhang
  • Kathryn M Mayer
  • Patty J Dennis
  • Emily A Oblath
  • Jean Pierre Alarie
  • Yue Wu
  • Frank G Oppenheim
  • Frédéric F Little
  • Ahmet Z Uluer
  • Peidong Wang
  • J Michael Ramsey
  • David R Walt
چکیده

During the last decade, saliva has emerged as a potentially ideal diagnostic biofluid for noninvasive testing. In this paper, we present an automated, integrated platform useable by minimally trained personnel in the field for the diagnosis of respiratory diseases using human saliva as a sample specimen. In this platform, a saliva sample is loaded onto a disposable microfluidic chip containing all the necessary reagents and components required for saliva analysis. The chip is then inserted into the automated analyzer, the SDReader, where multiple potential protein biomarkers for respiratory diseases are measured simultaneously using a microsphere-based array via fluorescence sandwich immunoassays. The results are read optically, and the images are analyzed by a custom-designed algorithm. The fully automated assay requires as little as 10 μL of saliva sample, and the results are reported in 70 min. The performance of the platform was characterized by testing protein standard solutions, and the results were comparable to those from the 3.5 h lab bench assay that we have previously reported. The device was also deployed in two clinical environments where 273 human saliva samples collected from different subjects were successfully tested, demonstrating the device's potential to assist clinicians with the diagnosis of respiratory diseases by providing timely protein biomarker profiling information. This platform, which combines noninvasive sample collection and fully automated analysis, can also be utilized in point-of-care diagnostics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rapid and Sensitive Method for Determina-tion of Morphine in Saliva of Opium Addicts

Background: Saliva is an alternative biological matrix in drug testing. It has several advantages in comparison with other biological fluids such as blood and urine. Collection of saliva is simple, noninvasive and can be controlled under direct observation in drug abusers, or opium addicts. Methods: In the present study we report our experience with saliva collection, liquid-liquid extraction a...

متن کامل

On-chip Protein Assays Using Microbead Arrays: an Integrated System for Salivary-based Clinical Diagnostics

A microfluidic device containing arrays of microwells filled with microbead sensors was used to perform protein assays in a saliva sample. Techniques for the fabrication of fully integrated arrays of microwells within polydimethylsiloxane (PDMS) microchannels were demonstrated. Subsequent microwell loading with stochastic arrays of encoded microbeads was performed and the devices were used for ...

متن کامل

Quantitative proteomic profiling of breast cancers using a multiplexed microfluidic platform for immunohistochemistry and immunocytochemistry.

This paper describes a multiplexed microfluidic immunohistochemistry (IHC)/immunocytochemistry (ICC) platform for quantitative proteomic profiling in breast cancer samples. Proteomic profiling via ICC was examined for four breast cancer cell lines (AU-565, HCC70, MCF-7, and SK-BR-3). The microfluidic device enabled 20 ICC assays on a biological specimen at the same time and a 16-fold decrease i...

متن کامل

Multi-Q: a fully automated tool for multiplexed protein quantitation.

The iTRAQ labeling method combined with shotgun proteomic techniques represents a new dimension in multiplexed quantitation for relative protein expression measurement in different cell states. To expedite the analysis of vast amounts of spectral data, we present a fully automated software package, called Multi-Q, for multiplexed iTRAQ-based quantitation in protein profiling. Multi-Q is designe...

متن کامل

Miniaturization of multiplexed planar recombinant antibody arrays for serum protein profiling.

BACKGROUND Antibody-based microarrays are a developing tool for high-throughput proteomics in health and disease. However, in order to enable global proteome profiling, novel miniaturized high-density antibody array formats must be developed. RESULTS In this proof-of-concept study, we have designed a miniaturized planar recombinant (single-chain Fragment variable). antibody array technology p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2014