Clinical experience with use of ultrasound sphygmomanometer.

نویسندگان

  • C F George
  • P J Lewis
  • A Petrie
چکیده

The performance of an ultrasound sphygmomanometer (Arteriosonde 1217) has been compared with that of the London School of Hygiene and Tropical Medicine and Hawksley sphygmomanometers. The Arteriosonde gave closely similar values of systolic blood pressure of the other instruments but diastolic blood pressure lay midway between phase 4 and phase 5 of the Korotkoff sounds. Observers using the Arteriosonde showed a significant preference for even terminal digits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short Term Outcome of Antenatal Hydronephrosis: A Single Center Experience

Background Fetal hydronephrosis is a common urinary tract anomaly that may result in renal parenchyma damage. Ultrasound is considered a simple, noninvasive procedure to diagnose and track antenatal hydronephrosis. Our aim was to study the clinical course of fetal hydronephrosis in fetuses. Materials and Methods</...

متن کامل

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

A comparison of the random-zero and standard mercury sphygmomanometers.

Both the standard mercury sphygmomanometer and the random-zero sphygmomanometer have been used in epidemiological studies and clinical trials. Problems arise in comparing studies since, in addition to other methodological differences, the readings obtained with the random-zero sphygmomanometer have been found to be lower than those obtained with the standard mercury sphygmomanometer. In the pre...

متن کامل

Evaluating the accuracy of an aneroid sphygmomanometer in a clinical trial setting.

BACKGROUND The mercury sphygmomanometer, the "gold" standard for blood pressure measurements, has been gradually phased out in many institutions because of environmental concerns. Our on-going clinical trial compared the use of mercury vs. aneroid sphygmomanometers, before implementing a study-wide transition to the aneroid sphygmomanometer. METHODS The Diabetes Prevention Program Outcomes St...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 1975