Improved analysis of brachial artery ultrasound using a novel edge-detection software system.

نویسندگان

  • R J Woodman
  • D A Playford
  • G F Watts
  • C Cheetham
  • C Reed
  • R R Taylor
  • I B Puddey
  • L J Beilin
  • V Burke
  • T A Mori
  • D Green
چکیده

Brachial artery ultrasound is commonly employed for noninvasive assessment of endothelial function. However, analysis is observer dependent and susceptible to errors. We describe studies on a computerized edge-detection and wall-tracking software program to allow more accurate and reproducible measurement. In study 1, three purpose-built Perspex phantom arteries, 3.00, 4.00, and 6.00 mm in diameter, were measured with the software. There was a mean bias of 11 microm (P < 0.001 at each level) between known and measured values; the mean resolving power of the software was estimated as 8.3 microm. In study 2, the mean intraobserver coefficient of variation of repeated measures of flow-mediated dilation (FMD) using the software (6.7%) was significantly lower than that for traditional manual measurements using the intima-lumen interfaces (24.8%, P < 0.05) and intima-media interfaces (32.5%, P < 0.05). In study 3, 24 healthy volunteers underwent repeat testing twice within 1 wk; the coefficients of variation for between-visit reproducibility of FMD and response to glyceryl trinitrate using the software were 14.7 and 17.6%, respectively. Assuming 80% power and an alpha of 0.05, eight subjects with matched controls would be required, in a parallel designed study, to detect an absolute 2.5% change in FMD. In summary, we have developed a semiautomated computerized vascular ultrasound analysis system that will improve the power of clinical intervention studies to detect small changes in arterial diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Different Edge Detections and Noise Reduction on Ultrasound Images of Carotid and Brachial Arteries Using a Speckle Reducing Anisotropic Diffusion Filter

BACKGROUND Common carotid artery (CCA) ultrasound with measurement of intima-media thickness (IMT) is a safe and noninvasive technique for assessing subclinical atherosclerosis and determining cardiovascular risks. Moreover, the pattern of wall thickening in the brachial artery (BA) is rather diffuse compared to the carotid artery and may be a more sensitive indicator of long-term systemic expo...

متن کامل

Diagnosis of Coronary Artery Disease via a Novel Fuzzy Expert System Optimized by Cuckoo Search

In this paper, we propose a novel fuzzy expert system for detection of Coronary Artery Disease, using cuckoo search algorithm. This system includes three phases: firstly, at the stage of fuzzy system design, a decision tree is used to extract if-then rules which provide the crisp rules required for Coronary Artery Disease detection. Secondly, the fuzzy system is formed by setting the intervals ...

متن کامل

Assessment of brachial artery blood flow across the cardiac cycle: retrograde flows during cycle ergometry.

We describe a novel software system that utilizes automated algorithms to perform edge detection and wall tracking of high-resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, to calculate conduit arterial blood flow (BF) across the cardiac cycle. Furthermore, we describe changes in brachial arterial BF to the resting forearm during increm...

متن کامل

Quad-pixel edge detection using neural network

One of the most fundamental features of digital image and the basic steps in image processing, analysis, pattern recognition and computer vision is the edge of an image where the preciseness and reliability of its results will affect directly on the comprehension machine system made objective world. Several edge detectors have been developed in the past decades, although no single edge detector...

متن کامل

Quad-pixel edge detection using neural network

One of the most fundamental features of digital image and the basic steps in image processing, analysis, pattern recognition and computer vision is the edge of an image where the preciseness and reliability of its results will affect directly on the comprehension machine system made objective world. Several edge detectors have been developed in the past decades, although no single edge detector...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 91 2  شماره 

صفحات  -

تاریخ انتشار 2001