Retrospective Comparison of Intermediate-term Efficacy of 350 mm2 Glaucoma Drainage Implants and Medium-sized 230-250 mm2 Implants
نویسندگان
چکیده
AIM To compare the intermediate-term efficacy of a large surface area Baerveldt 350 mm2 glaucoma drainage device (GDD) with medium surface area implants (Baerveldt 250 mm2 and Molteno 3, 230, or 245 mm2). DESIGN This is a retrospective, nonrandomized comparative trial. MATERIALS AND METHODS A total of 94 eyes of 94 patients of mixed glaucoma diagnoses without any prior glaucoma surgical procedures and who had undergone a glaucoma drainage implant surgery with either a large Baerveldt 350 mm2 GDD or a medium-sized GDD (Baerveldt 250 mm2 or Molteno 230 or 245 mm2) were reviewed for intraocular pressure (IOP), number of glaucoma medications, and visual acuity (VA) preoperatively, and at 1, 2, and 3 years postprocedure. RESULTS No significant differences were found in mean IOP, number of glaucoma medications used, and VA at 1, 2, and 3 years postoperatively. The rate of additional glaucoma procedures was similar between the two groups. CONCLUSION There is no clear evidence that a larger implant surface area beyond 230 to 250 mm2 is advantageous in providing intermediate-term IOP control. CLINICAL SIGNIFICANCE It may be technically easier to surgically place a GDD that does not need to have its wings placed underneath the recti muscles, and the IOP results are similar. HOW TO CITE THIS ARTICLE Meyer AM, Rodgers CD, Zou B, Rosenberg NC, Webel AD, Sherwood MB. Retrospective Comparison of Intermediate-term Efficacy of 350 mm2 Glaucoma Drainage Implants and Medium-sized 230-250 mm2 Implants. J Curr Glaucoma Pract 2017;11(1):8-15.
منابع مشابه
Otago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.
OBJECTIVE To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma. METHODS A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant. RESULTS Success was defi...
متن کاملIntrascleral outflow after deep sclerectomy with absorbable and non-absorbable implants in the rabbit eye
BACKGROUND The purpose of the study is an analysis of intrascleral drainage vessels formed in rabbits' eyes after non-penetrating deep sclerectomy (NPDS) with absorbable and non-absorbable implants, and comparison to eyes in which surgery was performed without implanted material. MATERIAL/METHODS NPDS was carried out in 12 rabbits, with implantation of non-absorbable methacrylic hydrogel (N=1...
متن کاملGlaucoma drainage implants: a critical comparison of types.
PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study popu...
متن کاملRelationship between Glaucoma Drainage Device Size and Intraocular Pressure Control: Does Size Matter?
There is ambiguity in the literature regarding whether a larger glaucoma drainage device (GDD) achieves a lower long-term intraocular pressure (IOP). There is some evidence on both sides, but overall there seems to be an optimal surface area of approximately 200-250 mm2 beyond which there may be little advantage to increasing the plate size for most patients. HOW TO CITE THIS ARTICLE Rodgers ...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کامل