Biphasic shocks compared with monophasic damped sine wave shocks for direct ventricular defibrillation during open heart surgery.
نویسندگان
چکیده
BACKGROUND Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraoperative energy dose-response curves. METHODS Patients undergoing cardiothoracic surgery with bypass cardioplegia were randomly assigned to the monophasic or biphasic shock group. Ventricular fibrillation occurring after aortic clamp removal was treated with escalating energies of 2, 5, 7, 10, and 20 J until defibrillation occurred. If ventricular fibrillation persisted, a 20-J crossover shock of the other waveform was used. RESULTS Cumulative defibrillation success at 5 J, the primary end point of the study, was higher in the biphasic group than in the monophasic group (25 of 50 vs. 9 of 41 defibrillated; P = 0.011). In addition, the biphasic group required lower threshold energy (6.8 vs. 11.0 J; P = 0.003), less cumulative energy (12.6 vs. 23.4 J; P = 0.002), and fewer shocks (2.5 vs. 3.5; P = 0.002). Crossover-shock effectiveness did not differ between groups. Dose-response curves show biphasic shocks to have higher cumulative success rates at all energies tested. CONCLUSIONS Biphasic shocks are substantially more effective than monophasic shocks for direct defibrillation. The dose-response curve guides selection of first-shock energy for traditional step-up protocols. Starting at 5 J optimizes for lowest threshold and cumulative energy, whereas 10 or 20 J optimizes for more rapid defibrillation and fewer shocks.
منابع مشابه
Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.
OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential...
متن کاملMulticenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation. Transthoracic Investigators.
BACKGROUND The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience ...
متن کاملTransthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks.
BACKGROUND Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS In this prospective, randomized, multic...
متن کاملThe effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function.
OBJECTIVES The purpose of this study was to compare the effects of biphasic defibrillation waveforms and conventional monophasic defibrillation waveforms on the success of initial defibrillation, postresuscitation myocardial function and duration of survival after prolonged ventricular fibrillation (VF). BACKGROUND We have recently demonstrated that the severity of postresuscitation myocardia...
متن کاملImproved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.
A reduction in the shock strength required for defibrillation would allow use of a smaller automatic implantable cardioverter-defibrillator and would reduce the possibility of myocardial damage by the shock. Most internal defibrillation electrodes require 5 to 25 J for successful defibrillation in human beings and in dogs. In an attempt to lower the shock strength needed for defibrillation, we ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 98 5 شماره
صفحات -
تاریخ انتشار 2003