Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis
نویسندگان
چکیده
BACKGROUND AND PURPOSE Periprosthetic bone loss after uncemented femoral hip revision is a matter of concern. We have used a proximally porous- and hydroxyapatite-coated prosthesis (Bi-Metric) in revision since 1989 and now we report the bone changes. This prosthesis is intended to distribute the forces more evenly and to avoid proximal femoral unloading. METHODS 22 patients were unilaterally reoperated because of aseptic loosening. Only patients with a healthy contralateral hip were included. Mean age at revision was 69 (55-80) years. Bone defects were graded by Gustilo-Pasternak and Endo-Klinik classifications. Clinical assessment was performed with Harris hip score. We used radiographs and dual-energy X-ray absorptiometry to evaluate migration, femoral remodeling, and bone mineral density after 72 (30-158) months. RESULTS The mean Harris hip score was 74 (30-100) points at follow-up. Mild thigh discomfort was present in 1 patient and moderate thigh pain in 3 patients. There was no loosening or subsidence. Osteolysis seen at revision had diminished in 19 of the 22 hips at follow-up. We noted a large reduction in bone mineral density. It was most pronounced in Gruen regions 1, 2, 6, and 7. INTERPRETATION Revision with this stem is a reliable procedure; however, we noted a large degree of proximal bone loss that could lead to later mechanical complications or fractures.
منابع مشابه
Results of uncemented porous-coated anatomic total hip replacement.
We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed gi...
متن کاملShort-term Outcomes With a Second-Generation Uncemented Stem in Total Hip Arthroplasty.
An uncemented stem has been used successfully in total hip arthroplasty for 2 decades, and some implants have been updated. The authors have used second-generation uncemented proximal porous coating stems, the Echo Bi-Metric Full Proximal Profile stem (Echo FPP; Biomet, Warsaw, Indiana) and the Echo Reduced Proximal Profile stem (Echo RPP; Biomet). This article reports short-term outcomes with ...
متن کاملEpidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.
AIMS The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). PATIENTS AND METHODS From our hospital's prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients' medical records and radiographs wer...
متن کاملTwenty-year survival of a cementless revision hip arthroplasty using a press-fit bulk acetabular allograft for pelvic discontinuity: a case report.
Acetabular revision in a total hip arthroplasty (THA) with pelvic discontinuity is uncommon and challenging. Optimal management remains controversial, particularly with graft and implant selection. Interpretation of outcomes is confounded by the heterogeneity of patterns of bone loss and the lack of long-term results in great numbers for any given choice of treatment. We report a revision THA u...
متن کاملLong-term results of the cementless porous-coated anatomic total hip prosthesis.
Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration ...
متن کامل