Diffusivity Measurements of Human Methemoglobin
نویسندگان
چکیده
Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25 degrees C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in this range decreased from 7.5 x 10(-7) cm(2)/sec to 1.6 x 10(-7) cm(2)/sec.
منابع مشابه
Studies of Methemoglobin Concentrations of Three Human Erythrocyte Genotypes (Hb AA, Hb AS, and Hb SS) in the Presence of Five Antimalarial Drugs
Background: Malaria remains the world’s most devastating human parasitic infection. Our goal was to assess the capacity of increasing concentrations of five antimalarial drugs (FansidarTM, HalfanTM, Quinine, CoartemTM and Chloroquine phosphate) to elicit the generation of methemoglobin in three human erythrocyte genotypes (Hb AA, Hb AS and Hb SS). Materials and Methods: Spectrophotometric metho...
متن کاملMeasurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.
BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...
متن کاملThe significant blood resistance to lung nitric oxide transfer lies within the red cell.
The lung nitric oxide (NO) diffusing capacity (DlNO) mainly reflects alveolar-capillary membrane conductance (Dm). However, blood resistance has been shown in vitro and in vivo. To explore whether this resistance lies in the plasma, the red blood cell (RBC) membrane, or in the RBC interior, we measured the NO diffusing capacity (Dno) in a membrane oxygenator circuit containing ∼1 liter of horse...
متن کاملSimultaneous determination of methemoglobin and total hemoglobin by a continuous-flow method.
We describe a sensitive, accurate automated method for the simultaneous measurement of methemoglobin and total hemoglobin in blood. The method can be used for either continuous in vivo monitoring or intermittent sampling at a rate of 20/h. Standardization procedures are described, in which human blood treated with sodium nitrite is used. Repeatability of methemoglobin and total hemoglobin measu...
متن کاملDevelopment of methemoglobin-based biological dosimetry in gamma–irradiated mice
Background: A new biological dosimeter based on methemoglobin level was developed in this study. Materials and Methods: Methemoglobin level in erythrocytes from mice subjected to &gamma rays from a 60Co source was detected using the methemoglobin kit. The dose range was from 0.5 to 8 Gy and the dose rate was 0.5 Gy/min. Results: The results demonstrate that methemoglobin level increases with in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of General Physiology
دوره 49 شماره
صفحات -
تاریخ انتشار 1966