Arrhythmia/Electrophysiology Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-Up The ALTITUDE Survival Study

نویسندگان

  • Leslie A. Saxon
  • David L. Hayes
  • Paul A. Heidenreich
  • Timothy E. Meyer
  • Paul W. Jones
  • John P. Boehmer
چکیده

Background—Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy– defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a network. Methods and Results—Survival status in patients implanted with ICD and CRT devices across the United States from a single manufacturer was assessed. Outcomes were compared between patients followed in device clinic settings and those who regularly transmit remote data collected from the device an average of 4 times monthly. Shock delivery and electrogram analysis could be ascertained from patients followed on the network, enabling survival after ICD shock to be evaluated. Oneand 5-year survival rates in 185 778 patients after ICD implantation were 92% and 68% and were 88% and 54% for CRT-D device recipients. In 8228 patients implanted with CRT-only devices, survival was 82% and 48% at 1 and 5 years, respectively. For the 69 556 ICD and CRT-D patients receiving remote follow-up on the network, 1and 5-year survival rates were higher compared with those in the 116 222 patients who received device follow-up in device clinics only (50% reduction; P 0.0001). There were no differences between patients followed on or off the remote network for the characteristics of age, gender, implanted device year or type, and economic or educational status. Shock therapy was associated with subsequent mortality risk for both ICD and CRT-D recipients. Conclusions—Survival after ICD and CRT-D implantation in patients treated in naturalistic practice compares favorably with survival rates observed in clinical trials. Remote follow-up of device data is associated with excellent survival, but arrhythmias that result in device therapy in this population are associated with a higher mortality risk compared with patients who do not require shock therapy. (Circulation. 2010;122:2359-2367.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study.

BACKGROUND Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a net...

متن کامل

An Assessment of Time Dependence of Defibrillator Benefit After Coronary Revascularization

Background: Previous studies have suggested that the benefit of implantable cardioverter defibrillator (ICD) implantation in patients following coronary revascularization (CR) may be related to time elapsed since revascularization, with those receiving the device > 6 months after the procedure deriving the greatest benefit. Methods: We evaluated 163 patients (141 M/22 F, age 67 ± 11 y, LVEF 30 ...

متن کامل

Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.

BACKGROUND The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought...

متن کامل

Influence of remote monitoring on long-term cardiovascular outcomes after cardioverter-defibrillator implantation.

AIMS Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS We performed a retrospective cohort study of consecutive...

متن کامل

Effects of Upgrade Versus De Novo Cardiac Resynchronization Therapy on Clinical Response and Long-Term Survival: Results from a Multicenter Study.

BACKGROUND Benefits of cardiac resynchronization therapy (CRT) on morbidity and mortality in selected patients are well known. Although the number of upgrade procedures from single- or dual-chamber devices to CRT is increasing, there are only sparse data on the outcomes of upgrade procedures compared with de novo CRT. This study aimed to evaluate clinical response and survival in patients recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010