Use of a disposable real-time CT stereotactic navigator device for minimally invasive dog brain biopsy through a mini-burr hole.
نویسندگان
چکیده
We assessed the feasibility, accuracy, and safety of securing site-selective brain biopsy specimens by using a real-time CT-guided stereotactic navigation system through a mini-burr hole in the skulls of two dogs. Two beagle dogs each underwent two biopsy procedures. Our results indicated that the navigation system was accurate, safe, fast, and reliable for performing real-time brain biopsy in dogs and eliminated the need or risk of a standard-flap craniotomy.
منابع مشابه
The Effectiveness of the Stereotactic Burr Hole Technique for Deep Brain Stimulation
Deep brain stimulation (DBS) is performed by burr hole surgery. In microelectrode recording by multi-channel parallel probe, because all microelectrodes do not always fit in the burr hole, additional drilling to enlarge the hole is occasionally required, which is time consuming and more invasive. We report a stereotactic burr hole technique to avoid additional drilling, and the efficacy of this...
متن کاملReal-time CT-guided spinal biopsy with a disposable stereotactic device: a technical note.
We compared eight spinal needle biopsy procedures performed with an investigational disposable real-time stereotactic device and eight spinal needle freehand biopsies in which a standard technique was used, to determine whether the investigational device added value to the procedure. The device uses a simple stereotactic diaphragm pattern to define two vector points. The procedures in which the...
متن کاملIntraoperative sonography through a burr hole: guide for brain biopsy.
Sonographic imaging of the brain was accomplished through a burr hole using a small, real-time, 5 MHz transducer in five patients. Brain tumors were accurately imaged, corresponding closely in morphology to the computed tomographic scan. Intraoperative sonography through a burr hole allows flexibility in technique and greatly facilitates brain biopsy procedures.
متن کاملLiquid Biopsy as a Minimally Invasive Source of Thyroid Cancer Genetic and Epigenetic Alterations
In the blood of cancer patients, some nucleic acid fragments and tumor cells can be found that make it possible to trace tumor changes through a simple blood test called “liquid biopsy”. The main components of liquid biopsy are fragments of DNA and RNA shed by tumors into the bloodstream and circulate freely( ctDNAs and ctRNAs). tumor cells which are shed into the blood (circulating tumor cells...
متن کاملPlacement of Deep Brain Electrodes in the Dog Using the Brainsight Frameless Stereotactic System: A Pilot Feasibility Study
BACKGROUND Deep brain stimulation (DBS) together with concurrent EEG recording has shown promise in the treatment of epilepsy. A novel device is capable of combining these 2 functions and may prove valuable in the treatment of epilepsy in dogs. However, stereotactic implantation of electrodes in dogs has not yet been evaluated. OBJECTIVE To evaluate the feasibility and safety of implanting st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 23 7 شماره
صفحات -
تاریخ انتشار 2002