Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy.

نویسندگان

  • Tom F Brouwer
  • Dilek Yilmaz
  • Robert Lindeboom
  • Maurits S Buiten
  • Louise R A Olde Nordkamp
  • Martin J Schalij
  • Arthur A Wilde
  • Lieselot van Erven
  • Reinoud E Knops
چکیده

BACKGROUND Transvenous implantable cardioverter-defibrillators (TV-ICDs) improve survival in patients at risk for sudden cardiac death, but complications remain an important drawback. The subcutaneous ICD (S-ICD) was developed to overcome lead-related complications. Comparison of clinical outcomes of both device types in previous studies was hampered by dissimilar patient characteristics. OBJECTIVES This retrospective study compares long-term clinical outcomes of S-ICD and TV-ICD therapy in a propensity-matched cohort. METHODS The authors analyzed 1,160 patients who underwent S-ICD or TV-ICD implantation in 2 high-volume hospitals in the Netherlands. Propensity matching for 16 baseline characteristics, including diagnosis, yielded 140 matched pairs. Clinical outcomes were device-related complications requiring surgical intervention, appropriate and inappropriate ICD therapy, and were reported as 5-year Kaplan-Meier rate estimates. RESULTS All 16 baseline characteristics were balanced in the matched cohort of 140 patients with S-ICDs and 140 patients with TV-ICDs (median age 41 years [interquartile range: 30 to 52 years] and 40% women). The complication rate was 13.7% in the S-ICD group versus 18.0% in the TV-ICD group (p = 0.80). The infection rate was 4.1% versus 3.6% in the TV-ICD groups (p = 0.36). Lead complications were lower in the S-ICD arm compared with the TV-ICD arm, 0.8% versus 11.5%, respectively (p = 0.03). S-ICD patients had more nonlead-related complications than TV-ICD patients, 9.9% versus 2.2%, respectively (p = 0.047). Appropriate ICD intervention (antitachycardia pacing and shocks) occurred more often in the TV-ICD group (hazard ratio [HR]: 2.42; p = 0.01). The incidence of appropriate (TV-ICD HR: 1.46; p = 0.36) and inappropriate shocks (TV-ICD HR: 0.85; p = 0.64) was similar. CONCLUSIONS The complication rate in patients implanted with an S-ICD or TV-ICD was similar, but their nature differed. The S-ICD reduced lead-related complications significantly, at the cost of nonlead-related complications. Rates of appropriate and inappropriate shocks were similar between the 2 groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subcutaneous Versus Transvenous Implantable Defibrillator Therapy

Fro of D Re Hu an Me rec Me rel Ma OBJECTIVES This study aims to conduct a meta-analysis comparing efficacy and safety outcomes between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous implantable cardioverter-defibrillator

متن کامل

Inappropriate shocks in a patient with a subcutaneous implantable cardioverter-defibrillator

The subcutaneous implantable cardioverter-defibrillator (ICD) is becoming more widespread. Approved by the Food and Drug Administration for use in the United Stated in 2012, the subcutaneous ICD is now being implanted for primary and secondary prevention of sudden cardiac death among individuals meeting conventional ICD implantation criteria but who do not have an indication for cardiac resynch...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Changing place, changing future: Repositioning a subcutaneous implantable cardioverter-defibrillator can resolve inappropriate shocks secondary to myopotential oversensing

Introduction The clinical benefits of implantable cardioverter-defibrillator (ICD) therapy have been widely documented in clinical studies of selected patient populations. Subcutaneous ICD (S-ICD) is a valid alternative to transvenous ICDinpatientswhodonot require cardiac resynchronization or antibradycardia or antitachycardia pacing, and has the additional advantage of avoiding possible acute ...

متن کامل

Totally submuscular implantation of subcutaneous implantable cardioverter defibrillator: a safe and effective solution for obese or oversized patients

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a safe alternative to transvenous ICD. We describe a submuscular S-ICD placement technique in a severely obese with an oversized chest. Submuscular configuration allows optimal system positioning and impendence values warranting a safe and effective shock transmission. This technique is safe and improves patients comfort.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 68 19  شماره 

صفحات  -

تاریخ انتشار 2016