Effect of connector design on fracture resistance of zirconia all-ceramic fixed partial dentures.

نویسندگان

  • Kozue Onodera
  • Toru Sato
  • Syuntaro Nomoto
  • Otoaki Miho
  • Mamoru Yotsuya
چکیده

The purpose of the present study was to determine the relationship between cross-sectional design and fracture load using a static load bearing test in yttria-stabilized tetragonal zirconia polycrystal ceramic frameworks on a molar fixed partial denture. The test framework was designed as a 3-unit bridge with two abutment teeth at the second premolar and second molar of the mandible. The cross-sectional area of the connector was 9.0, 7.0, or 5.0mm(2). In terms of shape, the cross-section was either circular or oval, with a height/width ratio of 1:1, 3:4, or 2:3. For each of the 9 combinations of cross-sectional area and shape, 5 frameworks were prepared (45 in total). Frameworks were cemented to a metallic test model with adhesive resin cement. After fracture load was measured, the percentage of fracture sites was determined and the fracture surfaces observed. In terms of cross-sectional area, there was a statistically significant difference in fracture load between 9.0, 7.0, and 5.0mm(2). No significant difference in fracture load was observed between any two shapes of connector (p>0.05). The fracture load of all frameworks with a cross-sectional area of 9.0 or 7.0mm(2) was over 880 N, which was recognized as parafunctional occlusal force. Fracture occurred at the distal connector in 82.2% of all frameworks on average. Fracture load decreased as cross-sectional area of the connector became smaller. The cross-sectional shape used in the present study was less influential on fracture load. It appears to be clinical possible to apply a connector with a cross-sectional area of 7.0mm(2). Fracture often occurred at the distal connector between the pontic and the abutment, corresponding to the second molar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of framework design on fracture resistance in zirconia 4-unit all-ceramic fixed partial dentures.

The purpose of this study was to conduct static load-bearing tests on 4-unit Y-TZP all-ceramic fixed partial denture (FPD) frameworks with different cross-sectional areas and forms to evaluate the influence of connector design on fracture load. Each of the central, mesial and distal connectors was prepared with one of 2 different cross-sectional areas and one of 3 different forms (one circular ...

متن کامل

The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness.

OBJECTIVES To assess the effect of interfacial surface roughness on the flexure strength and fracture mode and origin utilizing an in-vitro assessment of the clinical failure conditions expected for all-ceramic crowns and the connector area of fixed partial dentures (FPDs) using bilayered ceramic specimens tested in bi-axial flexure. METHODS Sets of 20 bilayered composite discs, with core:den...

متن کامل

Effect of Pontic Framework Design on the Fracture Resistance of Implant-supported All-ceramic Fixed Partial Dentures

OBJECTIVE The purpose of this study was to compare the fracture resistance of implant-supported all-ceramic fixed partial dentures, which have three different pontic designs. MATERIAL AND METHODS Two implants were placed in a metal model simulating mandibular left second premolar and mandibular left second molar. Thirty standardized 3-unit all-ceramic fixed partial dentures with biconvex, con...

متن کامل

اثر زیرکونیا بر استحکام خمشی سرامیک IPS Empress 2

Background and Aim: All ceramic, inlay-retained resin bonded fixed partial denture is a conservative method for replacement of missing teeth, because of minimal tooth reduction. The connector between the retainer and the pontic is the weak point of these bridges. Reinforcement of ceramic core will increase the clinical longevity. The aim of this study was to determine the effect of zirconia on ...

متن کامل

Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.

OBJECTIVES Tooth-coloured customised implant abutments and full ceramic supraconstructions thereon can be made of zirconia by computer-aided manufacturing (CAM). The aim of this study was to examine the potential limits of zirconia three-unit fixed partial dentures made on customised zirconia implant abutments in implant-tooth supported cases. MATERIAL AND METHODS Rigidly mounted implants (Xi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Bulletin of Tokyo Dental College

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2011