Friction burns within the tibia during reaming. Are they affected by the use of a tourniquet?
نویسندگان
چکیده
We have carried out a prospective, randomised trial to measure the rise of temperature during reaming of the tibia before intramedullary nailing. We studied 34 patients with a mean age of 35.1 years (18 to 63) and mean injury severity score of 10 (9 to 13). The patients were randomised into two groups: group 1 included 18 patients whose procedure was undertaken without a tourniquet and group 2, 16 patients in whom a tourniquet was used. The temperature in the bone was measured directly by two thermocouples inserted into the cortical bone near the isthmus of the tibial diaphysis. Reaming was carried out to at least 1.5 mm above the required diameter of the nail. Blood loss was assessed by recording the preoperative and postoperative haemoglobin (Hb) level. The minimum clinical follow-up was six months. In group 1 (no tourniquet), the mean Hb dropped 2.8 g/dl from 14.3 +/- 1.02 g/dl to 11.5 +/- 1.04 g/dl (p = 0.0001), whereas with the tourniquet, the mean decrease was 1.3 g/dl from 14 +/- 1 g/dl to 12.7 +/- 1.3 g/dl (p = 0.007). This difference was not statistically significant. The mean initial tibial temperature was 35.6 degrees C (SD 0.6) and rose with reaming to levels between 36.3 degrees C and 51.6 degrees C. The highest temperatures were obtained with the largest reamers (11 and 12 mm, p = 0.0001) and the most rapid rise with the smallest diameters of medullary canal (8 or 9 mm). The rise of temperature was transient (20 s). We were unable to identify any effect of the use of a tourniquet on the temperature achieved. Reamed intramedullary tibial nailing induces a transient elevation of temperature which is directly related to the amount of reaming.
منابع مشابه
Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases.
We present three young men who sustained closed diaphyseal fracture of the tibia and later developed severe osteocutaneous necrosis induced by heat during intramedullary reaming. They all had a narrow medullary cavity and in all a tourniquet had been used. Each developed a pretibial cutaneous blister soon after operation. In the following month severe osteomyelitis ensued, requiring segmental r...
متن کاملFriction burns to thigh caused by tourniquet.
surgery. It has been found to be a very safe device and the incidence of major complications associated with its use is as low as 1:13,000. Skin damage is a rare complication associated with the use of a pneumatic tourniquet. A few cases of chemical burns have been reported due to the use of alcohol based preparations, but friction burns due to the use of a tourniquet in a healthy person with n...
متن کاملThe use of intra-operative fluoroscopy for tibial tunnel placement in anterior cruciate ligament reconstruction
OBJECTIVES Our aim was to assess the use of intra-operative fluoroscopy in the assessment of the position of the tibial tunnel during reconstruction of the anterior cruciate ligament (ACL). METHODS Between January and June 2009 a total of 31 arthroscopic hamstring ACL reconstructions were performed. Intra-operative fluoroscopy was introduced (when available) to verify the position of the guid...
متن کاملAbnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet.
BACKGROUND In patients undergoing total knee arthroplasty, intraoperative pulmonary embolic events are rare, and most occur following tourniquet deflation. This embolization can be observed using transesophageal echocardiography. However, the authors have encountered sudden decreases in arterial oxygen partial pressure while a tourniquet is still inflated. Therefore, the current investigation w...
متن کاملبررسی شکستگیهای جوش نخورده تیبیا با استفاده از کونچر بعد از ریم کردن کانال داخل استخوان
Non-:::union::: is a complication in the management of patients who have a fracture of the tibia. The records of twenty patients who were treated by intramedullary nailing with reaming for non :::union::: of the tibia were reviewed. The fractures had been treated initially by closed reduction and immobilization in a cast, external fixation, fixation by pins in a plaster cast and dynamic comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 84 4 شماره
صفحات -
تاریخ انتشار 2002