Local delivery of gene vectors from bare-metal stents by use of a biodegradable synthetic complex inhibits in-stent restenosis in rat carotid arteries.

نویسندگان

  • Ilia Fishbein
  • Ivan Alferiev
  • Marina Bakay
  • Stanley J Stachelek
  • Peter Sobolewski
  • Meizan Lai
  • Hoon Choi
  • I-W Chen
  • Robert J Levy
چکیده

BACKGROUND Local drug delivery from polymer-coated stents has demonstrated efficacy for preventing in-stent restenosis; however, both the inflammatory effects of polymer coatings and concerns about late outcomes of drug-eluting stent use indicate the need to investigate innovative approaches, such as combining localized gene therapy with stent angioplasty. Thus, we investigated the hypothesis that adenoviral vectors (Ad) could be delivered from the bare-metal surfaces of stents with a synthetic complex for reversible vector binding. METHODS AND RESULTS We synthesized the 3 components of a gene vector binding complex: (1) A polyallylamine bisphosphonate with latent thiol groups (PABT), (2) a polyethyleneimine (PEI) with pyridyldithio groups for amplification of attachment sites [PEI(PDT)], and (3) a bifunctional (amine- and thiol-reactive) cross-linker with a labile ester bond (HL). HL-modified Ad attached to PABT/PEI(PDT)-treated steel surfaces demonstrated both sustained release in vitro over 30 days and localized green fluorescent protein expression in rat arterial smooth muscle cell cultures, which were not sensitive to either inhibition by neutralizing anti-Ad antibodies or inactivation after storage at 37 degrees C. In rat carotid studies, deployment of steel stents configured with PABT/PEI(PDT)/HL-tethered adenoviral vectors demonstrated both site-specific arterial Ad(GFP) expression and adenovirus-luciferase transgene activity per optical imaging. Rat carotid stent delivery of adenovirus encoding inducible nitric oxide synthase resulted in significant inhibition of restenosis. CONCLUSIONS Reversible immobilization of adenovirus vectors on the bare-metal surfaces of endovascular stents via a synthetic complex represents an efficient, tunable method for sustained release of gene vectors to the vasculature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model

BACKGROUND Carotid artery stenosis is a major risk factor for ischemic stroke. Although carotid angioplasty and stenting using an embolic protection device has been introduced as a less invasive carotid revascularization approach, in-stent restenosis limits its long-term efficacy and safety. The objective of this study was to test the anti-restenosis effects of local stent-mediated delivery of ...

متن کامل

Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent.

AIM The aim of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of a new biodegradable paclitaxel-loaded polylactide stent. Due to high rates of in-stent restenosis and permanent nature of metal stent implants, synthetic polymers have been proposed as surrogate materials for stents and local delivery systems for drugs. Paclitaxel was shown to inh...

متن کامل

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where restenosis is assessed after endothelial abrasion of the arterial wall or stent implantation. We combined endothelial cell denudation and implantation of stents to develop a new clinically relevant ...

متن کامل

The development of carotid stent material.

Endovascular angioplasty with stenting is a promising option for treating carotid artery stenosis. There exist a rapidly increasing number of different stent types with different materials. The bare-metal stent is the most commonly used stent with acceptable results, but it leaves us with the problems of thrombosis and restenosis. The drug-eluting stent is a breakthrough as it has the ability t...

متن کامل

Advances in Interventional Cardiology New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems

Drug-eluting stents (DES)were primarily conceived to reduce in-stent neointimal formation and therefore minimize the occurrence of restenosis, the major drawback of percutaneous coronary interventions with bare-metal stents (BMS). The development of DES has been pioneered through a combination of the increased understanding of the biology of restenosis, the selection of drugs that target 1 or m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 117 16  شماره 

صفحات  -

تاریخ انتشار 2008