Performance benchmarks of an array-based hand-held photoacoustic probe adapted from a clinical ultrasound system for non-invasive sentinel lymph node imaging.
نویسندگان
چکیده
Clinical translation of photoacoustic (PA) imaging can be facilitated by integration with commercial ultrasound (US) scanners to enable dual-modality imaging. An array-based US scanner was modified for hand-held PA imaging. The performance was benchmarked in terms of signal-to-noise ratio (SNR), axial spatial resolution and sensitivity. PA images of a tube, filled with methylene blue (MB; approx. 30 mM) and placed at various depths in chicken tissue, were acquired. A 5 cm penetration depth was achieved with an 18.6 dB SNR using a laser fluence of 3 mJ cm(-2), only one-seventh of the safety limit (20 mJ cm(-2)). An axial resolution of approximately 400 μm was maintained at all imaging depths. The PA sensitivity to MB placed 2.3 cm deep in chicken tissue was less than 100 μM. Further, after intradermal injection of MB (approx. 30 mM), a rat sentinel lymph node was clearly identified in vivo, beneath a 3.8 cm thick layer of chicken breast. The accumulated concentration of MB in the node was estimated to be approximately 7 mM. The noise-equivalent sensitivities (approx. 2 cm depth) were 17 and 85 μM, ex vivo and in vivo, respectively. These results support the use of this PA system for non-invasive mapping and image-guided needle biopsy of sentinel nodes in breast cancer patients.
منابع مشابه
Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Using a hand-held photoacoustic probe integrated with a clinical ultrasound array system, we successfully imaged objects deeply positioned in biological tissues. The optical contrasts were enhanced by methylene blue with a concentration of ~30 mM. The penetration depth reached ~5.2 cm in chicken breast tissue by using 650-nm wavelength, which is ~4.7 times the 1/e optical penetration depth. Thi...
متن کاملIn vivo three-dimensional photoacoustic imaging based on a clinical matrix array ultrasound probe.
We present an integrated photoacoustic and ultrasonic three-dimensional (3-D) volumetric imaging system based on a two-dimensional (2-D) matrix array ultrasound probe. A wavelength-tunable dye laser pumped by a Q-switched Nd:YAG laser serves as the light source and a modified commercial ultrasound imaging system (iU22, Philips Healthcare) with a 2-D array transducer (X7-2, Philips Healthcare) d...
متن کاملMonte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
متن کاملSentinel Node Mapping in Non-small Cell Lung Cancer Using an Intraoperative Radiotracer Technique
Objective(s): Lymph node metastases are the most significant prognostic factor in localized non-small cell lung cancer (NSCLC). Identification of the first nodal drainage site (sentinel node) may improve detection of metastatic nodes. Extended surgeries, such as lobectomy or pneumonectomy with lymph node dissection, are among the therapeutic options of higher acceptab...
متن کاملHandheld array-based photoacoustic probe for guiding needle biopsy of sentinel lymph nodes.
By modifying a clinical ultrasound array system, we develop a novel handheld photoacoustic probe for image-guided needle biopsy. The integration of optical fiber bundles for pulsed laser light delivery enables photoacoustic image-guided insertion of a needle into rat axillary lymph nodes with accumulated indocyanine green (ICG). Strong photoacoustic contrast of the needle is achieved. After sub...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Philosophical transactions. Series A, Mathematical, physical, and engineering sciences
دوره 369 1955 شماره
صفحات -
تاریخ انتشار 2011