Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting.

نویسندگان

  • Jong Hyeok Lee
  • Hee Eon Sohn
  • Seung Young Chung
  • Moon Sun Park
  • Seong Min Kim
  • Do Sung Lee
چکیده

OBJECTIVE The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. METHODS From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ≥70% were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. RESULTS CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). CONCLUSION Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes

AIM The objective of this study was to compare the periprocedural and clinical outcomes after carotid artery stenting (CAS) with proximal protection devices versus with distal protection devices. MATERIAL AND METHODS Patients with internal carotid artery (ICA) stenosis undergoing CAS with cerebral embolic protection were randomly assigned to proximal balloon occlusion or distal filter protect...

متن کامل

Advantages and Disadvantages of Distal Protection Filter Devices

Approximately 20 years ago, Jacque Theron suggested that embolic protection with balloon occlusion during carotid angioplasty could reduce procedure-related strokes.1 This was documented in his report, with a >50% reduction in strokes when using distal balloon occlusion. Henry et al2 described similar results using the PercuSurge balloon (Medtronic, Inc., Santa Rosa, CA) for distal protection. ...

متن کامل

Effect of two different neuroprotection systems on microembolization during carotid artery stenting.

OBJECTIVES This study sought to compare the efficacy of two different cerebral protection systems for the prevention of embolization during carotid artery stenting (CAS) using a transcranial Doppler (TCD) monitoring with the detection of microembolic signals (MES). BACKGROUND Despite the introduction of cerebral protection systems, neurologic complications during CAS cannot completely be prev...

متن کامل

Endovascular Stenting under Cardiac and Cerebral Protection for Subclavian Steal after Coronary Artery Bypass Grafting Due to Right Subclavian Artery Origin Stenosis

Coronary-subclavian steal (CSS) can occur after coronary artery bypass grafting (CABG) using the internal thoracic artery (ITA). Subclavian artery (SA) stenosis proximal to the ITA graft causes CSS. We describe a technique for cardiac and cerebral protection during endovascular stenting for CSS due to right SA origin stenosis after CABG. A 64-year-old man with a history of CABG using the right ...

متن کامل

Carotid artery stenting protected with an emboli containment system.

BACKGROUND AND PURPOSE Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. METHODS A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Korean Neurosurgical Society

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2015