Upper bound for neutron emission from sonoluminescing bubbles in deuterated acetone.
نویسندگان
چکیده
An experimental search for nuclear fusion inside imploding bubbles of degassed deuterated acetone at 0 degrees C driven by a 15 atm sound field and seeded with a neutron generator reveals an upper bound that is a factor of 10 000 less than the signal reported by Taleyarkhan et al. The strength of our upper bound is limited by the weakness of sonoluminescence, which we ascribe to the relatively high vapor pressure of acetone.
منابع مشابه
Comments on the possible observation of d-d fusion in sonoluminescence
We have repeated the experiment of Taleyarkhan et al. in an attempt to detect the emission of neutrons from d-d fusion during bubble collapse in deuterated acetone. Using the same apparatus, a more sophisticated data acquisition system, and a larger scintillator detector, we find no evidence for 2.5-MeV neutron emission correlated with sonoluminescence from the collapsing bubbles. Any neutron e...
متن کاملComments on the possible observation of d-d fusion in sonoluminescence
We have repeated the experiment of Taleyarkhan et al. in an attempt to detect the emission of neutrons from d-d fusion during bubble collapse in deuterated acetone. Using the same apparatus, a more sophisticated data acquisition system, and a larger scintillator detector, we find no evidence for 2.5-MeV neutron emission correlated with sonoluminescence from the collapsing bubbles. Any neutron e...
متن کاملNuclear fusion in collapsing bubbles-is it there? An attempt to repeat the observation of nuclear emissions from sonoluminescence.
We have repeated the experiment of Taleyarkhan et al. [Science 295, 1868 (2002)]] in an attempt to detect the emission of neutrons from d-d fusion during bubble collapse in deuterated acetone. Using the same cavitation apparatus, a more sophisticated data acquisition system, and a larger scintillator detector, we find no evidence for 2.5-MeV neutron emission correlated with sonoluminescence for...
متن کاملNuclear emissions during self-nucleated acoustic cavitation.
A unique, new stand-alone acoustic inertial confinement nuclear fusion test device was successfully tested. Experiments using four different liquid types were conducted in which bubbles were self-nucleated without the use of external neutrons. Four independent detection systems were used (i.e., a neutron track plastic detector to provide unambiguous visible records for fast neutrons, a detector...
متن کاملEvidence for nuclear emissions during acoustic cavitation revisited
This paper extends the experimental and numerical results presented previously and addresses the major criticisms raised. In addition, the most recent results are discussed. In acoustic cavitation experiments with chilled ( 0 8C) deuterated acetone (C3D6O), the production of tritium and 2.45 MeV neutrons [which are characteristic of deuterium-deuterium (D–D) fusion] was observed during vapour b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 98 6 شماره
صفحات -
تاریخ انتشار 2007