Improved determination of phenobarbital, primidone, and phenytoin by use of a preparative instrument for extraction, followed by gas chromatography.

نویسندگان

  • L M St Onge
  • E Dolar
  • M A Anglim
  • C J Least
چکیده

A microprocessor-controlled automatic extractor, (PREMTM I) is described with which lipophilic components may be extracted from physiological fluids by means of a selective, solid-phase extraction cartridge, and the extracts presented in dry form for subsequent analysis. This instrument has been successfully evaluated for the extraction of phenobarbital, primidone, and phenytoin from human serum before chromatographic analysis. We describe a specific method for determination of these anticonvulsants, involving the PREP I and analysis, after flash-heater methylation, in a gas chromatograph equipped with a nitrogen-sensitive detector. Absolute recoveries ranged from 90 to 102%. Within-day and day-to-day precision (CV) ranged from 4 to 7% for all three drugs in therapeutic concentrations. Comparison of this method with results obtained with a liquid--liquid micro-scale extraction and a similar gas-chromatographic method resulted in correlation coefficients of 0.988 (phenobarbital), 0.978 (primidone), and 0.982 (phenytoin). These drugs in therapeutic concentrations can be simultaneously extracted and measured with confidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of plasma procainamide and N-acetylprocainamide concentration by high-pressure liquid chromatography.

We describe a routine method for determining concentrations of the antiarrhythmic drug procainamide and its active metabolite, N-acetylprocainamide, in plasma. A simple extraction of 1.0 ml of plasma is followed by separation and chromatographic analysis by use of a column containing microparticulate silica. p-nitro-N-(2-diethylaminoethyl)benzamide hydrochloride was synthesized and used as the ...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Measurement of anticonvulsants in serum by reversed-phase ion-pair liquid chromatography.

We describe a method for the simultaneous liquid-chromatographic determination of ethosuximide, ethylphenacemide, primidone, phenobarbital, carbamazepine, and phenytoin in serum. The drugs, together with an internal standard, are extracted into ethyl acetate at pH 7.0. The extract is analyzed isocratically at ambient temperature on a reversed-phase column of "SAS Hypersil" with a mobile phase o...

متن کامل

Simultaneous gas-chromatographic analysis for phenobarbital, diphenylhydantoin, carbamazepine, and primidone in serum.

We describe a simple, sensitive determination of phenobarbital, diphenylhydantoin, carbamazepine, and primidone in serum, by use of gas-liquid chromatography with temperature programming. The methylated derivatives of these anticonvulsants are well resolved, as was 5-(p-methyl-phenyl)-5-phenylhydantoin, the internal standard. The proposed procedure requires only 0.20 ml of serum and can be done...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 1979