Coronary mra angiography at 3T: fat suppression versus water-fat separation

نویسندگان

  • Maryam Nezafat
  • Markus Henningsson
  • David P Ripley
  • Nathalie Dedieu
  • Gerald F Greil
  • John P Greenwood
  • Peter Börnert
  • Sven Plein
  • Rene Botnar
چکیده

Background Suppression of lipid signal is a basic requirement in coronary magnetic resonance angiography (CMRA) because coronary arteries are embedded in epicardial fat and signal from fat can decrease coronary vessel conspicuity. Most CMRA scans are currently performed with fat suppression techniques such as Spectral Presaturation with Inversion Recovery (SPIR). However, methods based on spectrally-selective fat saturation are sensitive to B0 and B1 field inhomogeneities. Recent improvements in chemical shift based water fat separation methods such as Dixon[1,2]provides an alternative to conventional spectrally-selective fat suppression techniques. The purpose of this study was to compare SPIR technique and Dixon water fat separation at 3.0 T for CMRA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation

Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...

متن کامل

Fat suppression for coronary MR angiography at 3T: 2 point Dixon versus Spectral Presaturation with Inversion Recovery (SPIR)

Background The coronary arteries are embedded in epicardial fat. To improve visualization in coronary MR angiography (CMRA) fat suppression techniques such as Spectral Presaturation with Inversion Recovery (SPIR) are often employed. Recently, water-fat separation using the multiecho 2 point Dixon method has gained increasing interest as it allows decomposing the MR signal into a water and fat i...

متن کامل

Diagnostic accuracy of Dixon water fat suppression coronary artery magnetic resonance angiography at 3.0 Tesla

Background X-Ray coronary angiography (XRA) remains the gold standard for assessment of coronary artery disease (CAD) although has associated clinical risk and financial cost. Coronary artery magnetic resonance angiography (CMRA) requires effective fat suppression as the epicardial vessels are embedded within fat. The aim of this study was to assess the diagnostic performance of non-contrast en...

متن کامل

Improved fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T2-Prep technique

Background In MRI, fat signal suppression is mandatory for unambiguous visualization of cardiac anatomy but remains challenging at high field. Fat saturation usually directly precedes the imaging portion of a cardiac MRI sequence. It is often used in conjunction with other magnetization preparation modules, such as T2 Preparation (or T2-Prep), to improve blood/myocardium contrast. We propose a ...

متن کامل

Automated pericardial fat quantification from coronary magnetic resonance angiography: feasibility study.

Pericardial fat volume (PFV) is emerging as an important parameter for cardiovascular risk stratification. We propose a hybrid approach for automated PFV quantification from water/fat-resolved whole-heart noncontrast coronary magnetic resonance angiography (MRA). Ten coronary MRA datasets were acquired. Image reconstruction and phase-based water-fat separation were conducted offline. Our propos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014