Relation between upper limit of vulnerability and defibrillation threshold in humans.

نویسندگان

  • P S Chen
  • G K Feld
  • J M Kriett
  • M M Mower
  • R Y Tarazi
  • R P Fleck
  • C D Swerdlow
  • E S Gang
  • R M Kass
چکیده

BACKGROUND In the canine model, an upper limit of shock strength exists that can induce ventricular fibrillation during the vulnerable period of the cardiac cycle. This shock strength (the upper limit of vulnerability) closely correlates with the defibrillation threshold and supports the "upper limit of vulnerability" hypothesis of defibrillation. It is not known whether an upper limit of vulnerability exists in humans or whether this limit correlates with the defibrillation threshold. METHODS AND RESULTS In 13 patients undergoing implantable cardioverter-defibrillator implantation, the shock strengths associated with a 50% probability of reaching the upper limit of vulnerability (ULV50) and a 50% probability of reaching the defibrillation threshold (DFT50) were determined by the up-down algorithm. The ULV50 was determined only for the mid-upslope of the positive T waves and for the mid-downslope of the negative T waves. No major complications occurred during surgery. An upper limit of vulnerability was demonstrated in each patient. The ULV50 was 300 +/- 138 V or 6.8 +/- 5.8 J, which was significantly lower than the DFT50 of 347 +/- 167 V (p = 0.038) or 9.1 +/- 7.3 J (p = 0.013). The correlation between the ULV50 and the DFT50 was significant (r = 0.90, p < 0.001 for voltage; r = 0.93, p < 0.001 for energy). CONCLUSIONS An upper limit of vulnerability is present in humans. There is a significant correlation between the ULV50 and the DFT50, and the ULV50 is significantly lower than the DFT50.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upper limit of vulnerability reliably predicts the defibrillation threshold in humans.

BACKGROUND The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implant...

متن کامل

Upper Limit of Vulnerabilit Reliably Predicts the Defibrillation Threshold in Humans

Background The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implant...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Effects of lidocaine on relation between defibrillation threshold and upper limit of vulnerability in open-chest dogs.

BACKGROUND The purpose of the present study was to test the effects of lidocaine on the relation between the defibrillation threshold and the upper limit of vulnerability. METHODS AND RESULTS The shock strength associated with a 50% probability of successful defibrillation (DFT50) and the shock strength associated with a 50% probability of reaching the upper limit of vulnerability (ULV50) wer...

متن کامل

Optical mapping of ventricular defibrillation in isolated swine right ventricles: demonstration of a postshock isoelectric window after near-threshold defibrillation shocks.

BACKGROUND Investigators who studied ventricular defibrillation by use of optical mapping techniques failed to observe an initial defibrillation event (isoelectric window or quiescent period) shown by electrode mapping studies. This discrepancy has important implications for the mechanisms of defibrillation. The purpose of the present study was to demonstrate an optical equivalent of an isoelec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 88 1  شماره 

صفحات  -

تاریخ انتشار 1993