Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

نویسندگان

  • Kazuki Matsuura
  • Yoshitsugu Inoue
چکیده

BACKGROUND The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL) insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD). METHODS Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations of IOLs and injectors used were: a three-piece shaped IOL, VA60BBR + TypeE1 (HOYA incision size 2.5 mm; group A, n=5); a single-piece IOL, 251+ iSert micro, preloaded (HOYA, incision size 2.2 mm; group G, n=5); and a single-piece IOL, SN6CWS preloaded (Alcon, incision size 2.7 mm; group C, n=5). RESULTS In group A, the intraocular OVD instantly flowed backward into the injector, whereas the colored OVD was pushed backward deep inside the cartridge without flowing into the eye. In group B, the backflow of the intraocular OVD into the injector was limited, resulting in the influx of a large amount of the colored OVD into the eye along with the IOL. In group C, as in group A, a large amount of the intraocular OVD flowed backward into the injector. Consequently, a small amount of the colored OVD flowed into the eye. CONCLUSION The tip of the injector and OVD could be contaminated because the surgical field cannot be completely sterile, even after preoperative disinfection. Our experiments revealed that OVD backflow into the injector cavity occurs during IOL insertion, and this phenomenon may have minimized intraocular contamination. However, small-diameter cartridges along with plate-type haptics allow insufficient OVD backflow, resulting in intraocular influx of the contaminated OVD. Surgeons have to be notified that intraoperative bacterial contamination can occur even after IOL insertion using injectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period

PURPOSE To compare the effect of two ocular viscosurgical devices (OVDs) on intraocular pressure (IOP) and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model) implantation. METHODS A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC) in one eye and 1% hyaluronic acid in fellow eye. Time ta...

متن کامل

Cataract Surgery Feature Story

OCTOBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 39 T he viscous and elastic properties of ophthalmic viscosurgical devices (OVDs) have numerous benefits in cataract surgery. Not only can they create and maintain space in the anterior chamber, but they can also protect and lubricate the corneal endothelium and displace and stabilize tissue. Most surgeons do not think twice about using an...

متن کامل

Surgical Technique for DMEK

Currently there are no FDA-approved DMEK injectors. American surgeons have found many creative off-label methods around this obstacle. Many surgeons use modified intraocular lens injection cartridges for this purpose. The Staar microinjector (Staar Surgical Company, Monrovia, CA) was one of the most common inserters initially used for DMEK in the US (Fig. 131.1B). The Staar injector is an open ...

متن کامل

Intraocular pressure during phacoemulsification.

PURPOSE To assess changes in intraocular pressure (IOP) during standard coaxial or bimanual microincision phacoemulsification. SETTING Oregon Eye Center, Eugene, Oregon, USA. METHODS Bimanual microincision phacoemulsification (microphaco) was performed in 3 cadaver eyes, and standard coaxial phacoemulsification was performed in 1 cadaver eye. A pressure transducer placed in the vitreous cav...

متن کامل

Hydro-visco-implantation Technique for Wound-assisted Foldable Intraocular Lens Implantation During Microincision Cataract Surgery

We have described a hydro-visco-implantation technique (simultaneous use of sodium hyaluronate and balanced salt solution) for wound-assisted intraocular lens (IOL) implantation and passive removal of ophthalmic viscosurgical device (OVD). In the technique, the capsular bag was filled approximately up to half with OVD, and anterior chamber was formed by bimanual irrigation cannula with continuo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014