Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint.

نویسندگان

  • Ibrahim Mutlu
  • Levent Ugur
  • Talip Celik
  • Levent Buluc
  • Umit Sefa Muezzinoglu
  • Yasin Kisioglu
چکیده

This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Patient-specific analysis of cartilage and labrum mechanics in human hips with acetabular dysplasia.

BACKGROUND Acetabular dysplasia is a major predisposing factor for development of hip osteoarthritis (OA), and may result from alterations to chondrolabral loading. Subject-specific finite element (FE) modeling can be used to evaluate chondrolabral mechanics in the dysplastic hip, thereby providing insight into mechanics that precede OA. OBJECTIVE To evaluate chondrolabral contact mechanics a...

متن کامل

Hip contact stress during normal and staircase walking: the influence of acetabular anteversion angle and lateral coverage of the acetabulum.

Hip contact stress is considered to be an important biomechanical factor related to development of coxarthrosis. The effect of the lateral coverage of the acetabulum on the hip contact stress has been demonstrated in several studies of hip dysplasia, whereas the effect of the anterior anteversion remains unclear. Therefore, the joint hip contact stress during normal level walking and staircase ...

متن کامل

Research Paper: Anthropometric Study of Hip Joint in Tehran Population Using Computed Tomography Scan

Introduction: Anthropometric studies provide valuable information in different populations. This study was conducted to evaluate the anatomical variations of the normal hip joint among Tehran population, Iran, in comparison with other populations. Methods: This study was carried out on hip joint of 260 patients in all ages and both genders referred to the Department of Radiology at Ebn-e Sina ...

متن کامل

Three-dimensional mechanical evaluation of joint contact pressure in 12 periacetabular osteotomy patients with 10-year follow-up

BACKGROUND AND PURPOSE Because of the varying structure of dysplastic hips, the optimal realignment of the joint during periacetabular osteotomy (PAO) may differ between patients. Three-dimensional (3D) mechanical and radiological analysis possibly accounts better for patient-specific morphology, and may improve and automate optimal joint realignment. PATIENTS AND METHODS We evaluated the 10-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2014