Improved Scan Efficiency of 3D Fast Spin Echo with Subspace-Constrained Reconstruction
نویسندگان
چکیده
Introduction: Scan efficiency plays a critical role in Fast Spin Echo (FSE) imaging because of the long TR intervals necessary to achieve the desired image contrast. Given a fixed scan-time budget, there are a finite number of TR intervals to collect echo trains, and this number is independent of the echo train length (ETL). However, in conventional reconstruction, long ETLs cause image blurring and mixed contrast due to uncompensated signal decay [1-3]. Model-based approaches that account for signal decay can overcome this limitation [4-8], but the impact of ETL is unclear when operating in an undersampled regime. In this work, we explore the utility of using a subspace-constrained reconstruction to increase ETLs without increasing noise or image blurring [7]. We show the approach has a fixed SNR cost, independent of ETL, compared to a reconstruction endowed with perfect knowledge of relaxation.
منابع مشابه
T2 Shuffling: Multicontrast 3D Fast Spin Echo Imaging
Introduction: Fast Spin Echo (FSE) sequences are the workhorse of MR imaging due to their speed and robustness to image artifacts. However, due to T2 decay, the reconstructed image suffers from blurring which grows with increasing echo train length (ETL) [1]. These drawbacks hinder the use of 3D FSE for musculoskeletal imaging, as the image quality attainable in the allotted scan time is not cl...
متن کاملReduced Blurring in 3D Fast Spin Echo through Joint Temporal ESPIRiT Reconstruction
Introduction: Volumetric (3D) Fast Spin Echo (FSE) is an attractive alternative to 2D FSE as it provides isotropic resolution. However, long echo trains are required to maintain scan efficiency, leading to blurring due to T2 decay [1]. Flip-angle modulation can reduce this effect [2], but blurring often persists, particularly in musculoskeletal applications. In this work, we aim to reduce blurr...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملHigh efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE)
We present an acquisition and reconstruction method designed to acquire high resolution 3D fast spin echo diffusion tensor images while mitigating the major sources of artifacts in DTI-field distortions, eddy currents and motion. The resulting images, being 3D, are of high SNR, and being fast spin echoes, exhibit greatly reduced field distortions. This sequence utilizes variable density spiral ...
متن کاملDetection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.
OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...
متن کامل