Low Cost Magnetic Resonance Imaging-Compatible Stepper Exercise Device for Use in Cardiac Stress Tests.

نویسندگان

  • Omid Forouzan
  • Evan Flink
  • Jared Warczytowa
  • Nick Thate
  • Andrew Hanske
  • Tongkeun Lee
  • Alejandro Roldan-Alzate
  • Chris François
  • Oliver Wieben
  • Naomi C Chesler
چکیده

Cardiovascular disease is the leading cause of death worldwide. Many cardiovascular diseases are better diagnosed during a cardiac stress test. Current approaches include either exercise or pharmacological stress echocardiography and pharmacological stress magnetic resonance imaging (MRI). MRI is the most accurate noninvasive method of assessing cardiac function. Currently there are very few exercise devices that allow collection of cardiovascular MRI data during exercise. We developed a low-cost exercise device that utilizes adjustable weight resistance and is compatible with magnetic resonance (MR) imaging. It is equipped with electronics that measure power output. Our device allows subjects to exercise with a leg-stepping motion while their torso is in the MR imager. The device is easy to mount on the MRI table and can be adjusted for different body sizes. Pilot tests were conducted with 5 healthy subjects (3 male and 2 female, 29.2 ± 3.9 yr old) showing significant exercise-induced changes in heart rate (+42%), cardiac output (+40%) and mean pulmonary artery (PA) flow (+%49) post exercise. These data demonstrate that our MR compatible stepper exercise device successfully generated a hemodynamically stressed state while allowing for high quality imaging. The adjustable weight resistance allows exercise stress testing of subjects with variable exercise capacities. This low-cost device has the potential to be used in a variety of pathologies that require a cardiac stress test for diagnosis and assessment of disease progression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial function and perfusion assessment with exercise stress cardiovascular magnetic resonance using an MRI-compatible treadmill in patients referred for stress SPECT

Background Exercise stress cardiac magnetic resonance (CMR) has recently become feasible with the development of a fully MRI-compatible treadmill system along with improvements in imaging techniques. The utility of this setup has not been systematically compared with nuclear perfusion imaging. The study objective was to evaluate the accuracy and prognostic value of exercise stress CMR with a tr...

متن کامل

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

Economic and biological costs of cardiac imaging

Medical imaging market consists of several billion tests per year worldwide. Out of these, at least one third are cardiovascular procedures. Keeping in mind that each test represents a cost, often a risk, and a diagnostic hypothesis, we can agree that every unnecessary and unjustifiable test is one test too many. Small individual costs, risks, and wastes multiplied by billions of examinations p...

متن کامل

Diagnostic Performance of Treadmill Exercise Cardiac Magnetic Resonance: The Prospective, Multicenter Exercise CMR's Accuracy for Cardiovascular Stress Testing (EXACT) Trial

BACKGROUND Stress cardiac magnetic resonance (CMR) has typically involved pharmacologic agents. Treadmill CMR has shown utility in single-center studies but has not undergone multicenter evaluation. METHODS AND RESULTS Patients referred for treadmill stress nuclear imaging (SPECT) were prospectively enrolled across 4 centers. After rest (99m)Tc SPECT, patients underwent resting cine CMR. In-r...

متن کامل

Disparity between dobutamine stress and physical exercise magnetic resonance imaging in patients with an intra-atrial correction for transposition of the great arteries.

BACKGROUND In patients with an intra-atrial correction for transposition of the great arteries (TGA) an abnormal response to stress testing is common. However, hemodynamic responses may vary substantially when different stress tests are used. We compared the hemodynamic response to dobutamine stress with the response to physical exercise in patients and controls. METHODS Thirty-nine patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical devices

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2014