Can a shorter psychomotor vigilance task be used as a reasonable substitute for the ten-minute psychomotor vigilance task?

نویسندگان

  • Gregory D Roach
  • Drew Dawson
  • Nicole Lamond
چکیده

The 10 min psychomotor vigilance task (PVT) is commonly used in laboratory studies to assess the impact of sleep loss, sustained wakefulness, and/or time of day on neurobehavioral performance. In field settings, though, it may be impractical for participants to perform a test of this length. The aim of this study was to identify a performance measure that is sensitive to the effects of fatigue but less burdensome than a 10 min test. Sixteen participants (11 female, 5 male; mean age = 21.7 years) slept in the sleep laboratory overnight then remained awake for 28 h from 08:00 h. During every second hour, participants completed three PVTs of differing duration (10 min, 5 min, 90 sec). For the 5 min/10 min comparison, ANOVA indicated that response time was significantly affected by test length (F1,14 = 26.9, p < .001) and hours of wakefulness (F13,182 = 46.1, p < .001) but not by their interaction (F13,182 = 1.7, ns). There was a strong correlation between response time on the 5 and 10 min PVTs (r = .88, p < .001). For the 90 sec/10 min comparison, ANOVA indicated that response time was significantly affected by test length (F1,14 = 65.9, p < .001) and hours of wakefulness (F13,182 = 29.7, p < .001) as well as by their interaction (F13,182 = 6.0, p < .001). There was a strong correlation between response time on the 90 sec and 10 min PVTs (r = .77, p < .001). The effects of hours of wakefulness on neurobehavioral performance were similar for the 5 min and 10 min PVTs. In contrast, performance on the 90 sec PVT was less affected by hours of wakefulness than on the 10 min PVT. In addition, performance on the 10 min PVT was more highly correlated with the 5 min PVT than the 90 sec PVT. These data indicate that the 5 min PVT may provide a reasonable substitute for the 10 min PVT in circumstances where a test shorter than 10 min is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Citicoline Improves Human Vigilance and Visual Working Memory: The Role of Neuronal Activation and Oxidative Stress

Introduction: Psychomotor performance task is used to assess the arousal and cognitive functions of the central nervous system. Alternatively, human visual working memory reflects the capability of the individual’s short-term memory. Psycho-mental stimuli are linked to the stimulation of Malondialdehyde (MDA) formations. Citicoline is a nootropic nucleotide agent with a favorable effect on the ...

متن کامل

Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task.

INTRODUCTION In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min version of the psychomotor vigilance task (PVT) specifically designed for use on personal digital assistants (PDA), to 28 h of sustained wakefulness. METHODS There were 15...

متن کامل

Tenth International Conference on Managing Fatigue: Abstract for Review Psychomotor Vigilance Task Evaluation for Touchscreen Devices

The Psychomotor Vigilance Task (PVT) is considered the gold standard fatigue detection device and is used frequently in fatigue research. With the rapid development of new technologies it is essential to develop PVT available on different platforms such as touchscreen devices. The big advantage of such PVT is that it can be implemented on small devices and can be easily used in field studies. T...

متن کامل

SHORT COMMUNICATION Fatigue Assessment in the Field: Validation of a Hand-Held Electronic Psychomotor Vigilance Task

LAMOND N, DAWSON D, ROACH GD. Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task. Aviat Space Environ Med 2005; 76:486–9. Introduction: In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min vers...

متن کامل

The sensitivity of a palm-based psychomotor vigilance task to severe sleep loss.

In this study, we evaluated the sensitivity of a 5-min personal digital assistant-psychomotor vigilance test (PDA-PVT) to severe sleep loss. Twenty-one participants completed a 10-min PVT-192 and a 5-min PDA-PVT at two hourly intervals during 62 h of sustained wakefulness. For both tasks, response speed and number of lapses (RTs > 500) per minute significantly increased with increasing hours of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chronobiology international

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2006