Assessment of the alveolar volume when sampling exhaled gas at different expired volumes in the single breath diffusion test

نویسندگان

  • Renato Prediletto
  • Edo Fornai
  • Giosuè Catapano
  • Cristina Carli
چکیده

BACKGROUND Alveolar volume measured according to the American Thoracic Society-European Respiratory Society (ATS-ERS) guidelines during the single breath diffusion test can be underestimated when there is maldistribution of ventilation. Therefore, the alveolar volume calculated by taking into account the ATS-ERS guidelines was compared to the alveolar volume measured from sequentiallly collected samples of the expired volume in two groups of individuals: COPD patients and healthy individuals. The aim of this study was to investigate the effects of the maldistribution of ventilation on the real estimate of alveolar volume and to evaluate some indicators suggestive of the presence of maldistribution of ventilation. METHODS Thirty healthy individuals and fifty patients with moderate-severe COPD were studied. The alveolar volume was measured either according to the ATS-ERS guidelines or considering the whole expired volume subdivided into five quintiles. An index reflecting the non-uniformity of the distribution of ventilation was then derived (DeltaVA/VE). RESULTS Significant differences were found when comparing the two measurements and the alveolar volume by quintiles appeared to have increased progressively towards residual volume in healthy individuals and much more in COPD patients. Therefore, DeltaVA/VE resulted in an abnormal increase in COPD. CONCLUSION The results of our study suggest that the alveolar volume during the single breath diffusion test should be measured through the collection of a sample of expired volume which could be more representative of the overall gas composition, especially in the presence of uneven distribution of ventilation. Further studies aimed at clarifying the final effects of this way of calculating the alveolar volume on the measure of DLCO are needed. DeltaVA/VE is an index that can help assess the severity of inhomogeneity in COPD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-Breath DLCO during Slow

KIKUCHI, R., SASAKI, T. and TAKISHIMA, T. Disappearance Curves and Single-Breath DLCO from Consecutive Samples during Slow Expiration. Tohoku J. exp. Med., 1982, 136 (4), 419-431 The disappearance of CO in three expirates consecutively sampled after various breath holding periods was measured in seven normal subjects. The CO disappearance curves in the three expired portions were nearly linear ...

متن کامل

The concept of deadspace with special reference to the single breath test for carbon dioxide.

We present a review and a theoretical analysis of factors determining airway deadspace (VDaw) and alveolar deadspace (VDalv), the two constituents of physiological deadspace (VDphys). VDaw if the volume of gas between the lips and the alveolar/fresh gas interface, the location of which is determined by inspiratory flow pattern and airway geometry. VDalv can be caused by incomplete alveolar gas ...

متن کامل

Accurate measurement of blood alcohol concentration with isothermal rebreathing.

The importance of interaction of exhaled air with the airway surface was evaluated by comparing the effects of different breathing maneuvers and inhaled air temperature on the relationship between breath alcohol concentration (BRAC) and blood alcohol concentration (BAC). Breath alcohol was measured with an infrared absorption unit. Blood and simulator liquid alcohol concentrations were measured...

متن کامل

Technique for gas-chromatographic measurement of volatile alkanes from single-breath samples.

For detection of small quantities of alkanes that are present in expired breath, these gases have hitherto been concentrated, either by passing large volumes of breath through a liquid-nitrogen-cooled precolumn or by use of a closed collection system. Here, we describe a technique for analyzing small volumes of gas from single-breath samples from humans, in which no precolumn is required. Resul...

متن کامل

Analyser position for end-tidal carbon dioxide monitoring in a rebreather circuit.

INTRODUCTION A diving rebreather currently nearing release incorporates an infra-red CO2 analyser at the end of the exhale hose and uses the expired gas CO2 measurement made at this position to detect hypercapnia. This configuration may allow exhaled anatomic and mouthpiece dead space gas to mix with alveolar gas in the exhale hose thus falsely lowering the CO2 measurement, especially at low ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Pulmonary Medicine

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007