Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.
نویسندگان
چکیده
To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored by miniature implantable radiation detectors for 4 hr after administration of the isotope. The dogs were then killed. Serial gamma camera images were also acquired during the study. Heart rate, arterial blood pressure, pressure distal to the stenosis, and cardiac output did not change significantly during the experiment. Microsphere-determined regional myocardial blood flow was significantly reduced in the left circumflex distribution in the 12 dogs with coronary artery stenoses. In the 12 dogs with left circumflex coronary artery stenoses, the 4 hr fractional Tc-MIBI clearances from the normal and ischemic zones were minimal and equivalent (0.15 +/- 0.05 vs 0.15 +/- 0.07). In the eight control dogs, 4 hr fractional Tc-MIBI clearances from the left anterior descending and left circumflex artery zones were minimal and equivalent (0.11 +/- 0.06 vs 0.10 +/- 0.07). Four hour fractional Tc-MIBI clearance from the blood was 0.98 +/- 0.03 for the dogs with stenosis and 0.97 +/- 0.02 for the dogs without stenosis. One additional dog had complete occlusion of the left circumflex coronary artery followed by administration of Tc-MIBI and scandium-46-labeled microspheres. This heart was immediately sectioned and counted to determine the relationship of regional blood flow to Tc-MIBI distribution (r = .92).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
LABORATORY INVESTIGATION NUCLEAR CARDIOLOGY Myocardial kinetics of technetium-99m-hexakis-2- methoxy-2-methylpropyl-isonitrile
To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored ...
متن کاملMyocardial kinetics of Tc-MIBI in canine myocardium after dipyridamole.
Technetium 99m-hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) is a promising new myocardial perfusion imaging agent producing excellent rest images. Imaging, however, will need to be performed with exercise or dipyridamole to detect ischemia and to differentiate salvaged but still ischemic myocardium from scar. Accordingly, 12 dogs were given mild-to-moderate left circumflex coronary ste...
متن کاملTechnetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.
Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.00...
متن کاملSingle Photon Emission Computed Tomography With Technetium-99m Hexakis 2~Methoxyisobutyl Isonitrile in Acute Myocardi~.I Infarction Before and After Thrombolytic Treatment: Assessment of Salvaged Myocardium and Prediction of Late Functional Recovery
Single photon emission computed tomography (SPECT) with technetium-99m hexakis 2-methoxyisobutyl isonitrile was investigated as a method to evaluate the results of intravenous thrombolytic treatment in 14 patients (11 men and 3 women) with acute myocardial infarction admitted to the coronary care unit within 4 h of the onset of symptoms. All patients received an injection of 740 MBq of the trac...
متن کاملArea-at-risk determination by technetium-99m-hexakis-2-methoxyisobutyl isonitrile in experimental reperfused myocardial infarction.
In a canine model of reperfused myocardial infarction, we tested the hypothesis that after reperfusion, technetium-99m-hexakis-2-methoxyisobutyl isonitrile (Tc-MIBI) tomographic imaging still reflects occlusion blood flow when the tracer is injected before reperfusion. Nine anesthetized dogs underwent 2 hours of coronary occlusion followed by 3 hours of reperfusion ending by being killed. Refer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 77 2 شماره
صفحات -
تاریخ انتشار 1988