Simultaneous Use of Cannulated Reamer and Schanz Screw for Closed Intramedullary Femoral Nailing

نویسندگان

  • Rajesh Rohilla
  • Roop Singh
  • Narender K. Magu
  • Ashish Devgan
  • Ramchander Siwach
  • Sukhbir Singh Sangwan
چکیده

Introduction. Closed reduction is a critical component of the intramedullary nailing and at times can be difficult and technically challenging resulting in increased operative time. Fluoroscopy is used extensively to achieve closed reduction which increases the intra-operative radiation exposure. Materials and Methods. Sixty patients with femoral diaphyseal fractures treated by locked intramedullary nailing were randomized in two groups. In group I, fracture reduction was performed under fluoroscopy with a cannulated reamer in the proximal fragment or with simultaneous use of a cannulated reamer in the proximal fragment and a Schanz screw in the distal fragment. Patients in group II had fracture reduction under fluoroscopy alone. Results. Closed reduction was achieved in 29 patients in group I and 25 patients in group II. The guide wire insertion time, time for nail insertion and its distal locking, total operative time, and total fluoroscopic time were 26.57, 27.93, 68.03, and 0.19 minutes in group I, compared with 30.87, 27.83, 69.93, and 0.24 minutes in group II, respectively. The average number of images taken to achieve guide wire insertion, for nail insertion and its locking and for the complete procedure in group I, respectively, was 12.33, 25.27, and 37.6 compared with 22.1, 26.17, and 48.27, respectively, in group II. Conclusion. The use of cannulated reamer in proximal fragment as intramedullary joystick and Schanz screw and in the distal fragment as percutaneous joystick facilitates closed reduction of the fracture during closed intramedullary femoral nailing with statistically significant reduction in guide wire insertion time and radiation exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Locked intramedullary femoral nailing without fracture table or image intensifier

The present retrospective study aims to evaluate the outcome in 41 patients of femoral shaft fractures, who had closed intramedullary nailing in lateral decubitus position without fracture table or image intensifier. Mean age was 33.2 (range, 18-70) years. The cannulated reamer in proximal fragment (as intramedullary joystick) and Schanz screw in the distal fragment (as percutaneous joystick) w...

متن کامل

Manipulation with Schanz screws for closed reduction of femoral shaft fractures during intramedullary nailing.

OBJECTIVE To use Schanz screws as a simple and effective method for closed reduction of femoral shaft fractures. METHODS In the present cohort study, which was carried out in Shohada Orthopedic Center, Tabriz, Iran between January 2004 and February 2005, 30 adult patients, with a mean age of 29 (18-65 years) with femoral shaft fractures underwent closed reduction with Schanz pins. The patient...

متن کامل

Bilateral Simultaneous Femoral Neck and Shafts Fractures – A Case Report

  Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression pl...

متن کامل

جا اندازی بسته و تثبیت شکستگی های تنه استخوان ران با استفاده از پیچهای شانز

Introduction & Objective: Closed intramedullary nailing has become the standard treatment for femoral shaft fractures, but because the existing closed reduction methods are difficult and demanding, in the most trauma centers these fractures usually are treated by open reduction method. Our objective was close reduction of these difficult fractures by a simple but effective method using Schanz...

متن کامل

Intramedullary Nailing of Femoral Shaft Fractures with Compressive Nailing Using Only Distal Dynamic Hole and Proximal Static Hole

Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal inter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011