Coronary Flow Interruption Following Balloon Rupture in an Elderly Patient
نویسندگان
چکیده
Jean-Jacques Monsuez1, Frédéric Pamoukdjian2, Samir Tine2, Soumaya Ikhefoulma3, Véronique François3, Georges Sebbane2 and Claude Le Feuvre4 1Department of Cardiology, University Hospital, Paris Seine Saint Denis, Hospital René Muret, France 2Department of Geriatry, Avicenne Hospital, University Hospitals of Paris Seine Saint Denis, France 3Department of Geriatry, Hospital René Muret, University Hospitals of Paris Seine Saint Denis, France 4Department of Cardiology, Pitié-Salpêtrière Hospital, Heart Institute, University of Paris 6, Faculty of Medicine, France *Corresponding author: Jean-Jacques Monsuez, AP-HP, Hôpital René Muret, Policlinic Medical Avenue du Docteur Schaeffner, F-93270 Sevran, France, Tel: 33-1-41525884; Fax: 33-1-141525863; E-mail: jean-jacques.monsuez @ aphp.fr
منابع مشابه
Simultaneous External Iliac Artery and Vein Rupture Following Percutaneous Balloon Angioplasty.
A 73-year-old woman who had undergone coronary artery bypass grafting for coronary artery stenosis six years ago, presented with right lower extremity claudication. Angiography revealed right external artery stenosis. Elective external iliac PTCA was performed complicated with simultaneous external iliac artery and vein rupture that was an exceedingly rare event. Retroperitoneal laparotomy with...
متن کاملCase Reports
Copyright © 2009 by the Congress of Neurological Surgeons Surgical clipping of paraclinoid region aneurysms can be challenging and often requires temporary interruption of local blood flow to decompress the aneurysm and to facilitate clip placement. This has traditionally been accomplished by trapping of the aneu rysm and suction decompression. Endo vascular balloon inflation across the aneurys...
متن کاملFlow velocity and predictors of a suboptimal coronary flow velocity reserve after coronary balloon angioplasty.
AIMS This study was conducted to analyse flow velocity parameters and predictors of a suboptimal coronary flow reserve (<2.5) following balloon angioplasty. METHODS Two hundred and twenty-five patients underwent sequential intracoronary Doppler as part of the DEBATE I study. Of these, 183, with complete angiography and Doppler at the 6-month follow-up, were included. Univariate and multivaria...
متن کاملRecurrent balloon rupture during Transcatheter Aortic Valve Replacement (TAVR) - a challenge to the Hybrid team.
Results We were successful in deploying a 26 mm Edwards Sapien XT through trans-aortic approach after two failed attempt due to rupture of the balloon during valvuloplasty. The patient also had an off pump coronary artery bypass grafting to the right coronary artery. The patient was discharged home after a week. Discussion/Conclusion TAVR balloon rupture is an uncommon complication; it could re...
متن کاملMyocardial free-wall rupture after acute infarction: survival aided by percutaneous intraaortic balloon counterpulsation.
After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...
متن کامل