Macular pigment optical density: repeatability, intereye correlation, and effect of ocular dominance
نویسندگان
چکیده
PURPOSE To evaluate short-term repeatability, intereye correlation, and effect of ocular dominance on macular pigment optical density (MPOD) measurements obtained using the QuantifEye Heterochromatic Flicker Photometer. PATIENTS AND METHODS A total of 72 study participants were enrolled in this prospective, cross-sectional study. Participants underwent a comprehensive ocular evaluation, including visual acuity, evaluation of ocular dominance, slit lamp examination, intraocular pressure measurement, and optic nerve head and macula analysis using optical coherence tomography and fundus photography. All study participants after initial training underwent MPOD measurement twice in both eyes in a randomized sequence. The repeatability was tested using Altman and Bland plots for first measurements with the second measurements for right eye and left eye and additionally by grouping eyes as a function of ocular dominance. The Pearson correlation coefficient was performed to assess the intereye correlation of MPOD values. RESULTS The mean age of study participants was 35.5 years (range 22-68 years). The mean MPOD measurements for OD (right eye) and OS (left eye) were 0.47 and 0.48, respectively, which followed a normal distribution (Shapiro-Wilk test, P=0.6 and 0.2). The 95% limits of agreement of Altman and Bland plots for the first and second measurements were -0.12 to +0.11 and -0.13 to +0.12 for OD and OS, respectively. The correlation coefficient of mean MPOD measurements of OD and OS was r statistic =0.94 (Pearson correlation coefficient P<0.0001; r (2) 0.89). The 95% limits of agreement of Altman and Bland plots when evaluated by laterality of eye or by ocular dominance were narrow, with limits of agreement ranging from -0.13 to +0.12. CONCLUSION The MPOD measurements obtained using the QuantifEye show good short-term repeatability. There is excellent intereye correlation, indicating that the MPOD values of one eye data can predict the fellow eye value with 89% accuracy. The ocular dominance had no bearing on the outcome of this psychophysical test in ocular healthy eyes.
منابع مشابه
Comparison of two methods to measure macular pigment optical density in healthy subjects.
PURPOSE To evaluate and compare macular pigment optical density (MPOD) measurements obtained using the modified Heidelberg Retina Angiograph (HRA) and the Visucam 200. METHODS Healthy young subjects were included in this prospective study. MPOD was measured with the modified HRA at 0° and 0.5°, 1°, 2°, and 6° eccentricities from the fovea. The parameters obtained with the Visucam 200 (maximum...
متن کاملMacular pigment and ocular biometry
This study is designed to investigate the relationship between macular pigment optical density (MPOD) and ocular biometric parameters. The following details were recorded for 180 healthy subjects: demographic profile; best-corrected visual acuity; refractive status; ocular biometric parameters [axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and vitreous chamber depth (VCD)...
متن کاملAn evaluation of a novel instrument for measuring macular pigment optical density: the MPS 9000.
PURPOSE Of the antioxidants found in the human retina, only the macular carotenoid quantities can be estimated noninvasively (albeit in a collective fashion), thus facilitating study of their role in that tissue. The aim of this study was to evaluate concordance between macular pigment optical density (MPOD) values recorded on a commercially available instrument, the MPS 9000, with those of an ...
متن کاملClinical evaluation of the MacuScope macular pigment densitometer.
BACKGROUND/AIMS The MacuScope uses a psychophysical technique called heterochromic flicker photometry to measure macular pigment optical density (MPOD). Our aim was to determine the measurement variability (noise) of the MacuScope. METHODS Thirty-eight normally sighted participants who ranged in age from 19 to 46 years (25.7+/-7.6 years) were recruited from staff and students of Aston Univers...
متن کاملAssociation of age and macular pigment optical density using dual-wavelength autofluorescence imaging
BACKGROUND Several lines of evidence suggest that macular pigment may play a protective role against age-related macular degeneration, but the influence of age on macular pigment density levels remains unclear. This study was designed to investigate the relationship between age and the normal distribution of macular pigment optical density (MPOD) values surrounding the fovea. METHODS Consecut...
متن کامل