Hybrid Warm Water Direct Cooling Solution Implementation in CS300-LC

نویسندگان

  • Roger L. Smith
  • Giridhar Chukkapalli
چکیده

In this white paper, the warm water direct liquid cooling solution implementation in the CCS cluster solution is described. First, literature review of a range of direct liquid cooling solutions implemented in various competing vendors and their pros and cons are briefly presented. Design choices of datacenter cooling water distribution mechanisms (single loop vs primary/secondary loops), types of cooling surfaces (sandwiched single milled metal plate vs individual heat sinks) and types of cooling fluids are reviewed. Next, business and technical constraints of the CCS cluster solution with respect to warm water cooling solution are reviewed. The bulk of the paper explains the implementation details of the hybrid direct liquid cooling solution within the CCS constraints of adhering to open standards and sensitivity to system TCO. The CS300-LC direct liquid cooling architecture implements a dual loop system isolating the high pressure datacenter loop from a completely sealed secondary IT loop via in-rack heat exchanger. Deionized water-glycol mixture is circulated to blade sub-racks through chassis manifolds and through drip free quick connectors to individual blades. Redundant low-power pumps circulate secondary fluid through CPU, Memory and accelerator heat sinks at very low pressure and flow rates. A remotely accessible PLC device monitors and manages the cooling system at the rack level. System design is such that compute blades are hot swappable and CPU, memory and individual pumps are field replaceable. In the hybrid cooling system, sub-rack level cooling fans run at lower speeds to extract residual heat thereby substantially reducing the fan power and noise. In the Cray CCS Lab, a prototype CS300-LC system is instrumented to measure temperatures, flow rates of liquid and air at inlets and outlets. Depending on the system configuration (CPU, memory and accelerators in a node), 60% to 85% of the heat is removed to warm water for a wide range of datacenter inlet water temperatures, and the rest of the heat is rejected to air or indirect cooling systems, hence the term hybrid. In addition, in collaboration between Cray Mississippi State University (MSU), additional detailed measurements will be conducted in a customer datacenter environment to understand energy efficiency and PUE. Additional details of resiliency, remote monitoring and management of the hybrid cooling system are described. The chassis level leak detection mechanism is described. How the CS300-LC cooling system reacts to rapidly changing application workloads and hence cooling loads is reported. The paper is concluded by exploring potential future work of making CS300-LC close to 100% warm water cooled and enhancements to Software tools needed for fine grained, tightly coupled management of the cooling system. Keywords-CS300-LC, direct coolimg, warm water, Xeon Phi, MIC, performance metrics

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition

Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...

متن کامل

Testing of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)

This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...

متن کامل

Chromatographic analysis of Polygalae Radix by online hyphenating pressurized liquid extraction

Practicing "green analytical chemistry" is of great importance when profiling the chemical composition of complex matrices. Herein, a novel hybrid analytical platform was developed for direct chemical analysis of complex matrices by online hyphenating pressurized warm water extraction followed by turbulent flow chromatography coupled with high performance liquid chromatography-tandem mass spect...

متن کامل

Calcareous nannofossil assemblages of the Late Campanian- Early Maastrichtian form Gurpi Formation (Dezful embayment, SW Iran): Evidence of a climate cooling event

A succession of Late Campanian- Early Maastrichtian is analyzed from Gurpi Formation with regard to the calcareous nannofossils. Correlation Matrix was applied for the first time to the entire nannofossil assemblage to reconstruct environmental conditions. A detailed quantitative calcareous nannofossil analyses is performed on samples in order to further investigate the climate events, and inte...

متن کامل

Novel PVA/La2Ce2O7 hybrid nanocomposite membranes for application in proton exchange membrane fuel cells

Proton exchange membrane fuel cells (PEMFCs) are electrochemical devices that show the highest power densities compared to the other type of fuel cell. In this work, nanocomposite membranes used for proton exchange membrane fuel cells as poly(vinyl alcohol)/La2Ce2O7 (PVA-LC) with the aim of increasing the water uptake and proton conductivity. Glutaraldehyde (GA) was used as cross linking agent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014