Efficacy of mechanical insufflation-exsufflation in extubating unweanable subjects with restrictive pulmonary disorders.

نویسندگان

  • John R Bach
  • Diane M Sinquee
  • Louis R Saporito
  • Amanda L Botticello
چکیده

BACKGROUND Subjects who do not pass ventilator weaning parameters but whose ambient air oxyhemoglobin saturation can be normalized by mechanical insufflation-exsufflation (MIE) can be extubated to continuous noninvasive ventilatory support (CNVS) with MIE used to maintain extubation. Our aim was to study MIE-associated changes in breathing tolerance, pulse oximetry, and vital capacity (VC) for consecutive unweanable subjects. METHODS A retrospective chart review was performed for consecutively referred intubated subjects with single-organ (respiratory muscle) failure. At presentation, CO2 was normalized by adjusting ventilator settings and VC was measured (point 1). Then, MIE was used via the tube up to every h until oximetry remained ≥ 95% on ambient air and VC was remeasured (point 2) immediately before extubation. Subjects who could not meet ventilator weaning criteria and had no ventilator-free breathing ability upon extubation to CNVS were enrolled. Post-extubation, the MIE was used to maintain oximetry ≥ 95% in room air. VC and breathing tolerance were remeasured within 3 weeks (point 3). RESULTS Ninety-seven of 98 subjects were successfully extubated despite 45 having been CNVS-dependent for 4 months to 18 y before being intubated. Sixty-nine of the 98 were intubated for 24.9 ± 22 (range 1-158) d and failed 0-6 (mean 1.7) extubation attempts before being transferred and successfully extubated in 2.24 ± 1.78 (range < 1-8) d to CNVS. VC increased by 270% (P < .001) from points 1 to 3. Weaning from CNVS to part-time NVS was achieved by all 52 subjects who had not been CNVS-dependent before intubation. One subject underwent tracheotomy. CONCLUSIONS Many unweanable subjects can be extubated to CNVS and MIE. The latter can normalize O2 saturation, increase VC, and facilitate extubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rate of oral intake and effects of mechanical insufflation-exsufflation on pulmonary complications in patients with duchenne muscular dystrophy

[Purpose] In Duchenne muscular dystrophy, it increases risks of difficulties of expectoration of secretion, asphyxia, aspiration pneumonia because of decreased cough function. The aim of this study is to prove that manually assisted coughing or mechanical insufflation-exsufflation prevents pulmonary complication and contribute to continue oral intake safely and continue rate of oral intake in D...

متن کامل

The use of mechanical insufflation-exsufflation via artificial airways.

During the past 20 years, airway clearance techniques have been the subject of increasing scientific interest. Cough augmentation with mechanical insufflation-exsufflation is part of this trend. No fewer than 23 studies, of which 21 were published in the past 10 years, have improved the level of evidence on this technique.1-23 As suggested in Figure 1, the availability of insufflation-exsufflat...

متن کامل

Cough augmentation with mechanical insufflation/exsufflation in patients with neuromuscular weakness.

Adults and children with neuromuscular disease exhibit weak cough and are susceptible to recurrent chest infections, a major cause of morbidity and mortality. Mechanical insufflation/exsufflation may improve cough efficacy by increasing peak cough flow. It was hypothesised that mechanical insufflation/exsufflation would produce a greater increase in peak cough flow than other modes of cough aug...

متن کامل

Mechanical insufflation-exsufflation for airway mucus clearance.

Cough is an important component of airway clearance, particularly in individuals with intrinsic pulmonary disease, weakness of respiratory muscles, or central nervous system disease that impairs breathing. The use of assisted cough to enhance airway clearance in individuals with neuromuscular disease is essential to produce and maintain peak cough flow above a minimum and thereby avoid retained...

متن کامل

Effect of High-Frequency Oscillations on Cough Peak Flows Generated by Mechanical In-Exsufflation in Medically Stable Subjects With Amyotrophic Lateral Sclerosis.

BACKGROUND Mechanically assisted coughing with mechanical in-exsufflation (MI-E) is recommended for noninvasive management of respiratory secretions in amyotrophic lateral sclerosis (ALS). To improve the effectiveness of the technique, a new device combining MI-E with high-frequency oscillations (HFO) has been developed. This work aimed to assess the effect of HFO on the cough peak flow generat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2015