Characteristics of telemetry interference with pacemakers caused by digital media players.

نویسندگان

  • Ashok J Shah
  • Joseph D Brunett
  • Jay P Thaker
  • Mehul B Patel
  • Valdis V Liepa
  • Krit Jongnarangsin
  • Ranjan K Thakur
چکیده

BACKGROUND Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. METHODS & RESULTS We studied the characteristics of interference with uplink (real time intracardiac electrograms, marker channel, and stored histograms) and downlink (attempt to program a change in the lower rate limit, the pacing mode, and the ventricular lead configuration) data transmission between the wand and the pacemaker caused by digital media players (iPods--Photo and 3G) in 50 patients. We also measured and characterized worst-case magnetic field emissions (MFE) from the wand (<or=0.4 microT), pacemaker (<or=0.004 microT), and iPod (<or=0.05 microT) during telemetry to understand the modulation techniques and safety protocols employed during data transmission. Telemetry interference (TI) manifested as high-frequency spikes (24.4%), blanking (17.7%) and interruption (22.2%), or delay (17.6%) in transmission with warning on programmer's screen. TI occurred in 25.6% of patients when the iPod was "on" and in 13% even with the iPod turned "off." There were no inaccuracies in downlinked data when the downlink communication was successful. Wanded telemetry utilizes low-frequency (30-300 kHz) radiowaves and simple digital modulation techniques at relatively slow rates for "sequential" data transmission protected by a continuous "handshake." Emissions from iPods in that range interrupt the telemetry link but are too weak to cause pacemaker malfunction through corruption of vital data. CONCLUSION Low-power MFE from iPods can produce interference with establishment and maintenance of a telemetry link and can cause TI with transmission of real time data, but because of continuous check protocols, do not corrupt the stored and vital downlink data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do media players cause interference with pacemakers?

BACKGROUND Electrical devices generate electromagnetic fields that may interfere with pacemakers. Media players cause telemetry interference with pacemakers, but it is not known whether they cause direct interference with pacemakers. The purpose of this study was to examine the interaction between pacemakers and 3 different media players. METHODS In this prospective, randomized study, 54 pati...

متن کامل

Interference between dental electrical devices and pacemakers or defibrillators: results from a prospective clinical study.

BACKGROUND The authors aimed to determine whether electrical dental devices would interfere with the function of cardiac pacemakers or implantable cardioverter defibrillators (ICDs) in humans. METHODS The authors exposed asymptomatic nonpacemaker-dependent patients to commonly used electrical dental equipment (for example, battery-operated curing lights, ultrasonic baths, ultrasonic scalers, ...

متن کامل

Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators - a retrospective multicenter investigation.

BACKGROUND & AIMS Capsule endoscopy (CE) is an established tool for the investigation of the small intestine. The Food and Drug Administration, Given Imaging and Olympus have not recommended the use of capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators (ICDs). The aim of this retrospective study was to investigate the safety of capsule endoscopy sy...

متن کامل

Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices

According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist d...

متن کامل

Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature

Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The vast majority of investigations did not reveal any interference between capsule endoscopy and ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2010