Sutureless technique to support anastomosis during thoracic aorta replacement

نویسندگان

  • Efstratios E Apostolakis
  • Vassilios N Leivaditis
  • Constantinos Anagnostopoulos
چکیده

BACKGROUND In aortic replacement procedures the aortic wall and Teflon strips form a double layer, with the use of continuous sutures. Surgical glues may or may not be used to enhance the durability of the anastomoses. In this technical report a modification of the aortic stumps preparation is devised.The technique reduces substantially the preparation time of the aortic stumps by the use of ligation clips and a surgical sealant. TECHNIQUE Suturing is the standard method for the aortic-teflon double-layer formation prior to Dacron anastomosis. In this study, instead of suturing, 5-6 ligation clips are primarily applied on the exterior of the double layer to facilitate proper cooptation. Secondarily, in order to fuse the two layers together, a sealant is injected in between the Teflon and aortic wall. Thus each stump is delivered quickly sutureless for the Dacron anastomosis.Between January 2003 and March 2009 this modified operative technique was performed in 14 cases (group A) with a mean age of 50 +/- 16 years. This was contrasted against 24 controls (group B), with a mean age of 40 +/- 28 years, treated with the conventional method, where only continuous sutures were used during the anastomosis. All patients were cases of ascending aorta replacement and/or aortic hemi-arch replacement, for acute aortic dissection or aortic dilatation. RESULTS The pure anastomosis time (stump preparation and Dacron connection) was shortened by approximately 25 minutes depending on surgeon's experience. The anastomosis blood-loss was also significantly reduced in the sutureless group A, as evident by the dry operative field and the limited use of blood products, post-prosthetic graft anastomosis. This reflected to a faster post-operative recovery, faster extubation and fewer complications. At a mean follow-up of 21 +/- 7 days, there were no post-operative deaths being related to acute aortic dissection or rupture of the anastomotic site. CONCLUSION Aortic replacement with the combination of ligation clips and a surgical sealant vs. sutures alone allows easy manipulations of the aorta and adaptation of the diameters, thus optimizing aortic operational timings and hemostasis. Moreover, it prevents blood loss and aortic wall trauma from multiple sutures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic valve replacement within an unexpected porcelain aorta: the sutureless valve option.

Four patients referred for surgical treatment of aortic stenosis presented an unexpected extremely calcified (porcelain) ascending aorta at the intraoperative epiaortic ultrasonography scanning. In each patient, replacement of the aortic valve was successfully performed using a sutureless implantable bioprosthesis during a short period of hypothermic circulatory arrest. In the era of transcathe...

متن کامل

Delayed dislocation of a sutureless aortic bioprosthesis: the first case.

Sutureless aortic bioprosthesis implantation is an alternative technique in high-risk patients undergoing aortic valve replacement with a possible reduction in the extracorporeal circuit time and reliable haemodynamic features. A 3F Enable (ATS Medical-Medtronic, Inc., Minneapolis, MN, USA) has shown very good results. We report the first upward displacement of 3F Enable three months post impla...

متن کامل

Valve-in-Valve Replacement Using a Sutureless Aortic Valve

BACKGROUND We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. CASE REPORT The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biop...

متن کامل

An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV) was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we...

متن کامل

Sutureless aortic valve replacement in stentless bioprosthesis failure.

Reoperation for a failed stentless bioprosthesis is an extremely challenging procedure due to severe adhesion around the previous stentless graft and the severely calcified aortic root. Although rarely the subject of reports in the literature, sutureless aortic valve replacement allows a fast and simple implantation, which decreases the risk of cardiac ischaemia and cardiopulmonary bypass. Here...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009