Stent strut thickness and restenosis.

نویسندگان

  • John A Ormiston
  • Mark W I Webster
  • Peter N Ruygrok
چکیده

To the Editor: Kastrati et al recently reported1 significantly less restenosis with lesions randomized to deployment of one stent design (ACS RX Multi-Link, [ML]) than with a related design (Multi-Link RX Duet, [DT]) from the same manufacturer (Guidant). They attributed the difference in restenosis to the difference in strut thickness. Although the two stent designs do differ significantly in strut thickness, there are other differences in design and mechanical properties that might impact on restenosis. The DT has greater radial strength: when tested in vitro in a pressure chamber, the DTs collapsed at a higher pressure (1.81 0.01 atm) than the MLs (0.77 0.03 atm, P 0. 05) (unpublished observations). Some experimental data suggest that greater stent hoop strength may cause increased neoimtimal proliferation.2 The extent of metal coverage of vessel wall is greater for the ML (22.3%) than for the DT (16.5%). The gap size or uncovered area between the stent struts also differs. The ML has gaps of one size (area 3.3 0.1 mm) whereas the DT has gaps of two sizes, one similar in size (3.3 0.4 mm) to the ML and one bigger (4.9 0.4 mm, P 0.01) (unpublished observations). The larger-sized gaps may allow greater tissue prolapse and increased restenosis analogous to the original Palmaz-Schatz stent where restenosis occurred mostly at the articulation site.3 On the other hand, we found no differences between the ML and the DT for expanded stent flexibility4 or for acute recoil, so these do not explain the difference in restenosis rates. Besides strut thickness, there are other differences in mechanical and physical properties between the expanded ML and DT stents that are equally plausible explanations for the differences in restenosis rates between the two designs. These differences may have implications for the design of stents with low restenosis rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.

OBJECTIVES We tested the hypothesis that thinner-strut stents are associated with a reduced rate of restenosis when comparing two stents with different design. BACKGROUND We have previously shown that, for two stents with similar design, the risk for restenosis is dependent on the strut thickness. It is unknown whether strut thickness preserves its relevance as a determinant of restenosis eve...

متن کامل

In-stent restenosis in small coronary arteries: impact of strut thickness.

UNLABELLED OBJECTIVES; We sought to evaluate whether strut thickness may impact the restenosis rate after stent implantation in small coronary arteries. BACKGROUND Small vessel size (<3.0 mm) is an independent risk factor for the occurrence of in-stent restenosis. It has been reported that vessel damage induced during stent deployment is an important factor in restenosis. METHODS From our d...

متن کامل

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

BACKGROUND Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to assess whether a reduced strut thickness of coronary stents is associated with improved follow-up angiographic and clinical results. METHODS AND RESULTS A total of 651 patients ...

متن کامل

Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design.

Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interven...

متن کامل

Predictors of restenosis after implantation of 2.5 mm stents in small coronary arteries.

BACKGROUND The results of stent implantation for small coronary disease have been inconclusive. The purpose of the present study was to evaluate the factors in predicting the risk of angiographic restenosis after 2.5-mm stent implantation for small coronary arteries. METHODS AND RESULTS The study group comprised 134 consecutive patients who had a reference small coronary artery with diameter ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 2  شماره 

صفحات  -

تاریخ انتشار 2002