Effective RF shielding with carbon fiber composites for simultaneous PET/MRI

نویسندگان

  • B. J. Peng
  • Y. Wu
  • S. R. Cherry
  • J. Walton
چکیده

Radio frequency (RF) interference and gradient induced eddy currents have been a major challenge in building a simultaneous PET/MRI system, a new carbon fiber composite material is found to be a good RF shield while introducing negligible gradient eddy currents. It also provides excellent structural support for the PET detector components. This material is therefore promising for the design of PET/MRI systems. Introduction: A prototype PET insert system has been built to be used simultaneously with a 7T (300 MHz) Bruker Biospec MR system [1]. In order to eliminate RF interference at 300 MHz, metal enclosures were used as shielding while placing these enclosures at a sufficient distance away from the MRI’s isocenter to minimize gradient-induced eddy current on these metal enclosures. Though the PET insert has shown promising results, its physical design limits potential further improvements, e.g. adding more detector rings to increase PET sensitivity and axial field of view. Eliminating the fiber optical bundle, which connects the scintillator to the photodetectors, and moving the photodetectors and their associated preamplifiers closer to the MRI isocenter while adding more detector rings, becomes the preferred approach. However, concerns regarding RF interference and gradientinduced eddy currents are the major hurdles to overcome. In order to minimize RF interference while minimizing gradientinduced eddy currents, a careful study of RF shielding design is essential. Carbon fiber (CF) materials have been studied as an effective RF shielding material [2]. In this abstract, preliminary data have shown that CF composite material is a promising RF shielding material for a simultaneous PET/MRI system. Materials and Methods: A 7T (300 MHz) Bruker Biospec MR system is used for this work. MRI gradient electronics are turned off. A single PET detector module is built consisting of an array of lutetium oxyorthosilicate (LSO) scintillator elements read out by a position sensitive avalanche photodiode (PSAPD). The PSAPD is then AC coupled to preamplifiers. The PET module was placed at the center of the RF coil. A Tektronix DsPO7254 oscilloscope (OS) is used to acquire data. Four data channels are recorded. Channel (Ch) 1 records raw PET data which is the readout of the preamplifier through a capacitor of 1 nF. Ch2 records one of the energy signals which is the output of the spectroscopy shaping amplifier. Ch3 records the timing signal of the PET detector which is the output of a constant-fraction discriminator (CFD). Ch4 is connected to a blanking pulse that is generated by the MRI RF amplifier electronics. It is used as a trigger to locate the 300 MHz RF signal. A single RF pulse at 300 MHz with duration of 20us, and 500ms repetition time is generated. For experiment #1, its transmission power is set at 13dB down from full power. All PET electronics are turned off. 300 MHz interference is observed by the OS. Seven sets of data are recorded with different shielding materials: 1) no shielding; 2) 0.001” thick copper (Cu) shielding, axial length 151mm, inner diameter (ID) 63 mm; 3) 0.002” thick Cu, with same dimensions; 4) 0.003” thick Cu with same dimensions; 5) carbon fiber (CF) shielding (purchased from CST Composites, Caringbah, NSW, Australia), axial length of 151mm, ID of 60mm and OD of 63mm; 6) The same CF shield with 0.003” Cu added; 7) a longer CF shield that has an axial length of 596mm with the same ID and OD. In experiment #2, the RF coil is shielded by the longer CF tube (shielding situation #7) and data is recorded while changing RF transmission power attenuation from 13dB to 1dB. Experiment #3 is a repeat of #1, except that the preamplifier power to the PET detector is now switched on. Three sets of data are studied under 3 different shielding conditions. 1) without shielding; 2) 0.003” thick Cu with axial length of 151mm; 3) 151mm long CF tube. Results and Discussion: The results of experiment #1 are shown in Table 1. Without RF shielding, an interference of 164.2 mV is generated by RF coil at 13dB. With better shielding, the interference is significantly reduced. Different thicknesses of Cu offer similar shielding effectiveness, but CF provides slightly better shielding. Adding additional Cu around the CF tube doesn’t improve shielding in this case. Remaining cross talk between the MRI’s RF and the PET detector module is due to radiation from the coaxial cable feeding the MRI RF coil. This is demonstrated via the improved shielding measured with the longer CF. Results of experiment #2 are shown in Fig.1. As transmitted RF power increases, RF interference increases as well. Nevertheless, even with high RF power, the CF provides effective shielding. For experiment #3, a sample of the observed RF interference is shown in Fig. 2 when no RF shield is used. Obviously strong RF interference is observed in the raw PET data (yellow, Ch1), two incidences of interference occur in the energy spectrum (blue, Ch2), and two unwanted pulses are found in timing signal (pink, Ch3) at the beginning and ending of the RF pulse. Note that green pulse is the blanking RF pulse used for triggering. Table 2 shows the RMS voltage of RF interference under the three different shielding conditions for experiment #3. When either 0.003” Cu or CF is used as shielding, interference in the energy spectrum and the timing spectrum cannot be observed on the OS even though very low (2.503 mV RMS) 300 MHz RF interference shows up in the raw PET spectra. In general, under an ideal PET operating environment, (e.g. 300 MHz is not present), a noise of 0.64mV RMS is observed on Ch1 of the OS when the preamp is turned off and 1.14mV RMS is observed when the preamp is powered on in the lab. When CF tube is used as shielding, RF interference is successfully reduced almost to noise levels. With better shielding on the RF cables, the CF tube shielded PET insert is capable of further reducing RF interference at 300 MHz to within the noise level of the PET detector preamplifier. References: [1] C. Catana, et al, “Simultaneous in vivo positron emission tomography and magnetic resonance imaging,” PNAS; 2008; 105(10), 37053710. [2] J. Keith, et al, “Shielding effectiveness density theory for carbon fiber/nylon 6,6 composites,” Polym. Compos.; 2005; 26:671-678 Proc. Intl. Soc. Mag. Reson. Med. 17 (2009) 3085

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solving RF Interference for a Simultaneous PET/MRI Scanner

Carbon fiber tubing is found to be excellent shielding against 300 MHz radiofrequency (RF) interference for the PET insert that is currently being developed for a 7T preclinical MRI system. Electrically grounding the PET detector module to the inner carbon fiber tube housing reduces low frequency RF noise. Adding thin copper (Cu) foil on the outer carbon fiber case while electrically grounding ...

متن کامل

FPGA-based RF interference reduction techniques for simultaneous PET–MRI

The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is ...

متن کامل

Pitch-matrix composites for electrical, electromagnetic and strain-sensing applications

Pitch-matrix composites for deicing, electromagnetic shielding and strain sensing have been developed by using carbon fiber (discontinuous) and carbon black as electrically conductive fillers. A composite with carbon fiber (5 vol%) as the sole filler is effective for strain sensing, which functions by the electrical resistivity increasing reversibly with tensile strain. A composite with carbon ...

متن کامل

PET/MRI insert using digital SiPMs: Investigation of MR-compatibility

In this work, we present an initial MR-compatibility study performed with the world's first preclinical PET/MR insert based on fully digital silicon photo multipliers (dSiPM). The PET insert allows simultaneous data acquisition of both imaging modalities and thus enables the true potential of hybrid PET/MRI. Since the PET insert has the potential to interfere with all of the MRI's subsystems (s...

متن کامل

Scalable Fabrication of Natural-Fiber Reinforced Composites with Electromagnetic Interference Shielding Properties by Incorporating Powdered Activated Carbon

Kenaf fiber-polyester composites incorporated with powdered activated carbon (PAC) were prepared using the vacuum-assisted resin transfer molding (VARTM) process. The product demonstrates the electromagnetic interference (EMI) shielding function. The kenaf fibers were retted in a pressured reactor to remove the lignin and extractives in the fiber. The PAC was loaded into the freshly retted fibe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008