Techniques for studying arterial elastic properties.
نویسنده
چکیده
Techniques for Studying Arterial Elastic Properties To the Editor: I applaud the effort of Rietzchel and colleagues1 to compare two techniques in wide use for studying arterial elastic properties. This is a study long in need of performance because of the controversial claims in the literature relating to the theory of systolic and diastolic waveform analysis. As we had anticipated and predicted,2 a reasonably good correlation was observed between the C2 measured by diastolic pulse wave analysis using a modified Windkessel analysis and late systolic augmentation index assessed using a transfer function previously described. The values from both of these techniques apparently relate, at least in part, to reflected waves from the peripheral small arteries. The augmentation index is also critically dependent on large artery pulse wave velocity that accounts for appearance of the reflected wave at the root of the aorta in late systole. The C2 also may have some dependency on large artery elasticity, but fortunately an independent assessment of this large artery elasticity is also available from the calculation of C1 in the modified Windkessel model. The authors of the study have, however, performed a disservice by their flawed analysis of their data. They claim that the variability of C2 (33.3% by their calculation) is much greater than the variability of augmentation index (6.7%), and they imply that this “wide gap” might make the C2 measurements of less diagnostic precision. But variability of a diagnostic tool can only be evaluated in relation to the range of absolute values to be anticipated. The range of AIx observed in their studies was from about 80% to 180%, a 125% range. The range of C2 was from about 1 to 14 mL/mm Hg 100, a 1300% range. The diagnostic precision for AIx could then be estimated as 125/6.7 or 19, whereas the diagnostic precision of C2 would be 1300/33.3 or 39. Because both of these tests provide a range of values from normal (young) to abnormal (old), a 33% variability in C2 would have even less impact on diagnostic precision than a 6.7% variability in AIx. The authors also demonstrate some bias in their interpretation of Figure 4, which analyzes the differences observed in regression lines describing C2 and AIx. They assume in their analysis that the C2 is inaccurate, whereas it is equally plausible that the inaccuracy is in the AIx calculation. Critical analyses of methodology require the absence of bias and a pristine assessment of data. We regret that the authors’ analysis appears to have fallen short of that standard and thus may have misled users of these instruments.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملResonance Ultrasonic Spectroscopy of a Nanofibrous Composite and Studying the Effect of Surface/Interface
Resonances are intrinsic characteristics of an elastic object, which are completely independent of the source of excitation. The appropriate utilization of the information contained within the resonance spectra and the identification of the resonance frequencies of the object can be used as a potent tool for material characterization. In this paper, a new mathematical model for the wave diffrac...
متن کاملVascular elastic laminae: anti-inflammatory properties and potential applications to arterial reconstruction.
Biomaterials, including non-biodegradable and biodegradable polymers, and collagen and fibrin matrices, have been used in experimental and clinical arterial reconstruction. While these biomaterials exhibit various characteristics suitable for arterial reconstruction, the patency of biomaterial-based arterial substitutes remains problematic because of inflammation and thrombogenesis. Endothelial...
متن کاملDynamic Analysis of Axially Beam on Visco - Elastic Foundation with Elastic Supports under Moving Load
For dynamic analyses of railway track structures, the algorithm of solution is very important. For estimating the important problems in the railway tracks such as the effects of rail joints, rail supports, rail modeling in the nearness of bridge and other problems, the models of the axially beam model on the elastic foundation can be utilized. For studying the effects of axially beam on the ela...
متن کاملIncreased stiffness and cell-matrix interactions of abdominal aorta in two experimental nonhypertensive models: long-term chemically sympathectomized and sinoaortic denervated rats.
RATIONALE Sinoaortic denervated (SAD) and chemically sympathectomized (SNX) rats are characterized by a decrease in arterial distensibility without hypertension and would, thus, be relevant for analyzing arterial wall stiffening independently of blood pressure level. The fibronectin network, which plays a pivotal role in cell-matrix interactions, is a major determinant of arterial stiffness. We...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hypertension
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2002